Patton electronic 07MSMARTMEDIA-SCG Universal Remote User Manual


 
Configuring an M2UA System on a Signaling Gateway 155
Smart Media Software Configuration Guide 5 • Configuring SIGTRAN Applications
For a system on a signaling gateway: Select an MTP2 link
F
or a system on a media gateway controller: Select NONE
Select a p
rotocol type (same as MTP2)
Select an i
nterface ID type
Enter an appropriate int
erface ID (must be unique to each link)
–Click Cre
ate
Figure 245. Creating a New M2UA Link
3. Verify that the "M2ua Link was successfully created" message displays:
Figure 246. Successful M2UA Link Message
Understanding Parameters for M2UA Links
Table 53. Configuration Parameters for New M2UA Links
Parameter Description
Name Used by the Web Portal to indicate a specific object or string in the system
MTP2 Link Selects an MTP2 link to bind to an object
Protocol Type Identifies the SS7 protocol variant that will be used with a particular object.
The appropriate protocol variant depends on the user's geographical loca-
tion. Values are chosen from a drop-down list. The Protocol Type parameter
can
take on the following values, depending on the object being config-
ured:
ITU
ITU88
ITU92
ITU97
TELCORDIA
ANSI88
ANSI92
ANSI95
SINGAPORE
Q767
TTC
NTT
CHINA
ETSI
ETSIV3
UK
Interface ID Type Defines the data type of an M2UA Link's interface ID. Possible values:
Integer/String
Interface ID Identifies the interface of an M2UA link