Patton electronic 07MSMARTMEDIA-SCG Universal Remote User Manual


 
Configuring the MTP2 Layer 85
Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
Understanding Parameters for MTP2 Links
Table 16. Configuration Parameters for New MTP2 Links
Parameter Description
Name Used by the Web Portal to indicate a specific object or string in the system
Connection Mode Defines the type of connection used in an SS7 system. Possible values:
Normal/Hsl (High-speed link)
Line Service Indicates which TDM line service is to be associated with the object being created
Timeslots Allows the selection of individual voice or data channels of a line. Values for this
parameter are listed as check boxes (ranging from 1-24). Individual timeslots can
be selected by checking the boxes. Occasionally, all timeslots can be selected at
once by clicking the Select All link.
Protocol Type Identifies the SS7 protocol variant that will be used with a particular object. The
appropriate protocol variant depends on the user's geographical location. Values
are chosen from a drop-down list. The Protocol Type parameter can take on the
following values, depending on the object being configured:
ITU
ITU88
ITU92
ITU97
TELCORDIA
ANSI88
ANSI92
ANSI95
SINGAPORE
Q767
TTC
NTT
CHINA
ETSI
ETSIV3
UK
DPC Length Sets a format for the Destination Point Code (DPC) used by an object.
Possible values: 14bits format=3.8.3/16bits format=7.4.5/24bits format=8.8.8
Timeslot Rate Indicates the data rate for timeslots on a line. Possible values:
64 Kbps/56 Kbps/48 Kbps