Creating an M3UA Configuration (SGP)
To set up your M3UA system on a signaling gateway process (SGP), you must first create a new M3UA config-
uration. In this configuration the SS7 MTP2 layer is replaced entirely by the SIGTRAN M3UA layer, and the
MT
P3 layer is extended over the IP network. To create an M3UA configuration on an SGP:
1. Se
lect M3UA from the navigation panel:
Figure 298. SS7 > M3UA
2. Configure the M3UA service for SGP:
–Enter a na
me for the configuration
Select Si
gnaling Gateway Process (SGP) as the node type
–Click Cre
ate
Figure 299. Creating the New M3UA (SGP) Configuration
3. Verify that the "M3uaCfg was successfully updated" message displays.
Figure 300. Successful Configuration Message
Understanding Parameters for M3UA Configurations
Table 69. Configuration Parameters for New M3UA Configurations
Parameter Description
Name Used by the Web Portal to indicate a specific object or string in the system
Node Type Assigns a configuration to an M3UA network. Possible values:
Signaling Gateway Process (SGP)
Application Server Process (ASP)
IP Server Process (IPSP)