12 UDC 3300 Controller Product Manual 4/00
2.2 Model Number Interpretation
Model number
The model number interpretationis shown in Figure 2-1. Write the model
number into the spaces provided and compare it to the model number
interpretation. This information will also be useful when you wire your
controller.
Figure 2-1 Model Number Interpretation
24151
0DC3 3 0
Table VITable VTable IVTable IIITable IITable IKey Number
Output #1
C0
=
K –
=
E –
=
A –
=
S –
=
T –
=
Output #2 or Alarm #2
– 0
=
– E
=
– A
=
– S
=
– T
=
B
=
E
=
L
=
D
=
Basic Controller Model
Expanded Controller Model
Limit Controller Model
Basic Model with UDC 3000 DMCS
Functionality
Current without Alarms or Output 2
Current with Alarm 1
Relay, E-M with Alarm 1
Relay, SS 1 amp with Alarm 1
Relay, SS 10 amp with Alarm 1
Open Collector Output
None
Relay, E-M
Relay, SS 1 amp
Relay, SS 10 amp
Open Collector Output
External Interface
0 ––
=
1 ––
=
2 ––
=
4 ––
=
5 ––
=
Software Options
– 0 –
=
– A –
=
– B –
=
– C –
=
– D –
=
– E –
=
Digital Inputs
–– 0
=
–– 3
=
None
RS422/485 ASCII / Modbus
Auxiliary Output (Loop 2 Current Output)
DMCS Communications
Auxiliary Output + RS422/485 / Modbus
Standard Functions (includes Accutune II)
Setpoint Programming (SPP)—DMCS Model
SPP
Math Option + SPP
2 Loops/Internal Cascade + SPP
Math Option + 2 Loops/Internal Cascade +
SPP
None
Two Digital Inputs
PV Input
1 –
=
2 –
=
3 –
=
1 5
=
1 6
=
Optional Input(s)
– 0
=
– 1
=
– 2
=
– 3
=
– 4
=
T/C, RTD, Radiamatic, mV, 0-5V, 1-5V
T/C, RTD, Radiamatic, mV, 0-5V, 1-5V, 0-20 mA, 4-20 mA
T/C, RTD, Radiamatic, mV, 0-5V, 1-5V, 0-20 mA, 4-20 mA,
0-10V
Relative Humidity (includes optional input)
Carbon, Oxygen, or Dewpoint (includes optional input)
None
T/C, RTD, Radiamatic, mV, 0-5V, 1-5V, 0-20 mA, 4-20 mA
Slidewire Input
T/C, RTD, Radiamatic, mV, 0-5V, 1-5V, 0-20 mA, 4-20 mA,
0-10V
Two High Level AIs instead of 2nd Universal AI
Options
0 –––––
=
1 –––––
=
– 0 ––––
=
– A ––––
=
– F ––––
=
––0 –––
=
–– B –––
=
–– T –––
=
––– 0 ––
=
––– P ––
=
––– T ––
=
––– U ––
=
–––– 0 –
=
–––– D –
=
––––– 0
=
90 to 264 Vac Power
24 Vac/dc Power
None
CSA, FM, and UL
FM and UL
Gray Elastomer Bezel
Blue Elastomer Bezel
Tan Elastomer Bezel
None
Rear Terminal Cover
Customer ID Tag
Rear Terminal Cover & Tag
None
DIN Cutout Adapter
None
Manuals
0 –
=
F –
=
G –
=
T –
=
S –
=
Certificate
– 0
=
– C
=
English
French
German
Italian
Spanish
None
Certificate of Conformance
(F3391)
– F –
= Math Option + SPP + HealthWatch
– G –
= 2 Loops/Internal Cascade + SPP +
HealthWatch
– H –
= Math Option + 2 Loops/Internal Cascade +
SPP + HealthWatch
– 1 –
= Standard Functions (includes Accutune II
and HealthWatch)