Baldor mn792 Universal Remote User Manual


 
Keypad Operation 7-7MN792
3 button reset
(Changing the Power Base). This is only necessary if you are installing a new control board on an existing
power base. Powerup the drive holding three keys as described in Figure 7-6.
It is important that the control be configured for the correct power rating damage may occur to the drive when it
attempts to run the motor.
Continue to select the correct product code rating. Perform a parameter save now (refer to Save Settings).
Figure 7-6 3 Button Reset
Hold down these three keys:
Powerup the drive, continue to
hold the keys for 2 seconds.
M TO SET PCODE
E TO SAVE PCODE
E TO SAVE PCODE
PRODUCT CODE
PRODUCT CODE
DC 4Q 15A
PRODUCT CODE
DC 2Q 15A
E TO SAVE PCODE
PRODUCT CODE
M TO SET PCODE
E TO SAVE PCODE
BALDOR DC DRIVE
DC 2Q 15A
s
t
E
PROG
M
M
s
E
E
E
HOLD
Choices are: Product Code (pick list)
Zero Cal Inputs (up to action)
Platform (STD/Elev)
250% ilimit (true/false)
This is the preferred way of selecting a new product code. The available product codes are restricted to the set
of codes that match the power base.
If the product code is changed during the 3button reset, the following parameters are set to their factory value
for the new product code:
Tag [523] ARMATURE CURRENT
Tag [524] FIELD CURRENT
Tag [201] REGEN MODE
The 3button reset does not cause the factory configuration to be loaded.