Baldor mn792 Universal Remote User Manual


 
Keypad Operation 7-11MN792
Save Settings
When parameter values have been changed they are not permanent until they are saved. If you turn power off
then turn power on, the previous settings (stored in memory) will be used. To make your new parameter
settings the power up settings, they must be saved to nonvolatile memory. These new values are always used
until this procedure is used to write new values to nonvolatile memory.
Note: Always ensure that Configure I/O = Disabled before doing a Parameter Save. If Configure I/O =
Enabled, the control cannot run the motor.
Action Description Display Comments
Press B
Scroll to SYSTEM menu.
MENU LEVEL
SYSTEM
Press M key
SYSTEM
CONFIGURE I/O
Press M key
CONFIGURE I/O
ENABLED
Press Y or B key
Select Disabled.
CONFIGURE I/O
DISABLED
Press E key Exit one level
SYSTEM
CONFIGURE I/O
Press E key Exit one level
MENU LEVEL
SYSTEM
Press B
Scroll to PARAMETER SAVE menu.
MENU LEVEL
PARAMETER SAVE
Press M key
PARAMETER SAVE
UP TO ACTION
Press Y Press Y to save parameters.
PARAMETER SAVE
REQUESTED
Parameters are saved. Except the
Local Setpoint.
Press E key Exit one level
MENU LEVEL
PARAMETER SAVE
Press E several times to return to
the top level.
Note: The Local Setpoint value is not saved as a parameter.
1 SYSTEM
2 CONFIGURE I/O
CONFIGURE ENABLE
1 PARAMETER SAVE
PARAMETER SAVE