Parameter Table B-31MN792
Table B-4 Parameters Listed by WB Block Continued
Tag R/W Name Keypad Menu WB Block Range Factory Setting MN Notes
119 RW I DMD. ISOLATE SETUP PARAMETERS::CURRENT LOOP Current Loop 0 : Disabled 1 : Enabled Disabled db
17 RW INT. GAIN SETUP PARAMETERS::CURRENT LOOP Current Loop 0.00 to 200.00 3.50 ah
421 RW MAIN CURR. LIMIT SETUP PARAMETERS::CURRENT LOOP Current Loop 0.00 to 200.00 % 200.00% lp
527 RO Master Bridge SETUP PARAMETERS::CURRENT LOOP Current Loop 0 : Off 1 : On Off on Output, 1
48 RW NEG. I CLAMP SETUP PARAMETERS::CURRENT LOOP Current Loop -100.00 to 100.00 % 0.00% bc
301 RW POS. I CLAMP SETUP PARAMETERS::CURRENT LOOP Current Loop -100.00 to 100.00 % 100.00% id
16 RW PROP. GAIN SETUP PARAMETERS::CURRENT LOOP Current Loop 0.00 to 200.00 45.00 ag
201 RW Regen Mode SETUP PARAMETERS::CURRENT LOOP Current Loop 0 : 2Q (Non-regen)
1 : 4Q (Regen)
2Q(Non-regen) fl 2
93 RW IMAX BRK1(SPD1) SETUP PARAMETERS::CURRENT PROFILE Current Profile 0.00 to 200.00 % (h) 200.00% cl 2
33 RW IMAX BRK2(SPD2) SETUP PARAMETERS::CURRENT PROFILE Current Profile 0.00 to 200.00 % (h) 200.00% ax 2
32 RW SPD BRK1 (LOW) SETUP PARAMETERS::CURRENT PROFILE Current Profile 0.00 to 100.00 % (h) 100.00% aw 2
31 RW SPD BRK2 (HIGH) SETUP PARAMETERS::CURRENT PROFILE Current Profile 0.00 to 100.00 % (h) 100.00% av 2
61 RO ACTUAL NEG I LIM DIAGNOSTICS Diagnostics xxx.xx % (h) -90.0% bp Output
67 RO ACTUAL POS I LIM DIAGNOSTICS Diagnostics xxx.xx % (h) 90.00% bv Output
299 RO Current Demand DIAGNOSTICS Diagnostics xxx.xx % 0.00% ib Output
298 RO Current Feedback DIAGNOSTICS Diagnostics xxx.xx % 0.00% ia Output
84 RO Drive Enable DIAGNOSTICS Diagnostics 0 : Disabled 1 : Enabled Disabled cc Output
82 RO Drive Start DIAGNOSTICS Diagnostics 0 : Off 1 : On Off ca Output
206 RO Encoder DIAGNOSTICS Diagnostics xxxxx RPM 0 RPM fq Output
300 RO FIELD I FBK. DIAGNOSTICS Diagnostics xxx.xx % 0.00% ic Output
88 RO NEG. I CLAMP DIAGNOSTICS Diagnostics xxx.xx % (h) -90.0% cg Output
87 RO POS. I CLAMP DIAGNOSTICS Diagnostics xxx.xx % (h) 90.0% cf Output
297 RO Speed Error DIAGNOSTICS Diagnostics xxx.xx % -0.01% i9 Output
207 RO Speed Feedback DIAGNOSTICS Diagnostics xxx.xx % 0.01% fr Output
308 RO Tach Input DIAGNOSTICS Diagnostics xxx.xx % (h) 0.0% ik Output
494 RW Destination Tag SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGITAL INPUT C4
Dig in C4 0 to 549 496 nq 2, 3
495 RW Destination Tag SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGITAL INPUT C5
Dig in C5 0 to 549 497 nr 2, 3
71 RO DIGIN 1 (C6) DIAGNOSTICS Digital Input 1 0 : Off 1 : On Off bz Output
102 RW Destination Tag SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 1 (C6)
Digital Input 1 0 to 549 90 cu 2, 3
104 RW Value For False SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 1 (C6)
Digital Input 1 -300.00 to 300.00 % 0.00% cw
103 RW Value For True SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 1 (C6)
Digital Input 1 -300.00 to 300.00 % 0.01% cv
72 RO DIGIN 2 (C7) DIAGNOSTICS Digital Input 2 0 : Off 1 : On Off c0 Output
105 RW Destination Tag SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 2 (C7)
Digital Input 2 0 to 549 118 cx 2, 3
107 RW Value For False SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 2 (C7)
Digital Input 2 -300.00 to 300.00 % 0.00% cz
106 RW Value For True SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 2 (C7)
Digital Input 2 -300.00 to 300.00 % 0.01% cy
73 RO DIGIN 3 (C8) DIAGNOSTICS Digital Input 3 0 : Off 1 : On Off c1 Output
108 RW Destination Tag SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 3 (C8)
Digital Input 3 0 to 549 119 d0 2, 3
110 RW Value For False SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 3 (C8)
Digital Input 3 -300.00 to 300.00 % 0.00% d2
109 RW Value For True SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 3 (C8)
Digital Input 3 -300.00 to 300.00 % 0.01% d1
74 RO DIGOUT 1 (B5) DIAGNOSTICS Digout 1 (B5) 0 : Off 1 : On On c2 Output
359 RW Inverted SYSTEM::CONFIGURE I/O::DIGITAL OUTĆ
PUTS::DIGOUT 1 (B5)
Digout 1 (B5) 0 : False 1 : True FALSE jz
43 RW Modulus SYSTEM::CONFIGURE I/O::DIGITAL OUTĆ
PUTS::DIGOUT 1 (B5)
Digout 1 (B5) 0 : False 1 : True TRUE b7
97 RW Source Tag SYSTEM::CONFIGURE I/O::DIGITAL OUTĆ
PUTS::DIGOUT 1 (B5)
Digout 1 (B5) 0 to 549 77 cp 2, 3
195 RW Threshold (>) SYSTEM::CONFIGURE I/O::DIGITAL OUTĆ
PUTS::DIGOUT 1 (B5)
Digout 1 (B5) -300.00 to 300.00 % 0.00% ff 2
75 RO DIGOUT 2 (B6) DIAGNOSTICS Digout 2 (B6) 0 : Off 1 : On On c3 Output