Baldor mn792 Universal Remote User Manual


 
B-16 Parameter Table MN792
Table B-2 Parameters Listed by Name Continued
Tag R/W Name Keypad Menu WB Block Range Factory Setting MN Notes
540 RW REM Trip Inhibit SETUP PARAMETERS::INHIBIT ALARMS Alarms 0 : Enabled 1 : Inhibited Enabled p0
535 RW REM.SEQ.ENABLE SETUP PARAMETERS::AUX I/O Aux I/O 0 : False, 1 : True FALSE ov 2
536 RW REM.SEQUENCE SETUP PARAMETERS::AUX I/O Aux I/O 0x0000 to 0xFFFF 0x0000 ow 1
542 RO Remote Trip ALARM STATUS Alarms 0 : False 1 : True FALSE p2 Output, 1
255 RW Reset Value SETUP PARAMETERS::RAISE/LOWER Raise/Lower -300.00 to 300.00 % 0.00% h3
422 RW Reset Value SETUP PARAMETERS::RAMPS Ramps -300.00 to 300.00 % 0.00% lq
189 RO Scaled Input SERIAL LINKS::SYSTEM PORT (P3)::P3 SETĆ
UP::5703 SUPPORT
5703 xxx.xx % 0.00% f9 Output, 2
537 RO SEQ Status SETUP PARAMETERS::AUX I/O Aux I/O 0x0000 to 0xFFFF 0x0C03 ox Output
171 RW Setpoint SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS
Field Control 0.00 to 100.00 % 100.00% er
512 RW Setpoint SETUP PARAMETERS::OP STATION::SET UP Op Station 0.00 to 100.00 % 0.00% o8 1
519 RW Setpoint SETUP PARAMETERS::OP STATION::START
UP VALUES
Op Station 0.00 to 100.00 % 0.00% of
289 RW Setpoint 1 SETUP PARAMETERS::SPEED LOOP::SETĆ
POINTS
Speed Loop -105.00 to 105.00 % 0.00% i1
290 RO Setpoint 2 (A3) SETUP PARAMETERS::SPEED LOOP::SETĆ
POINTS
Speed Loop xxx.xx % 0.00% i2 Output
291 RW Setpoint 3 SETUP PARAMETERS::SPEED LOOP::SETĆ
POINTS
Speed Loop -105.00 to 105.00 % 0.00% i3
41 RW Setpoint 4 SETUP PARAMETERS::SPEED LOOP::SETĆ
POINTS
Speed Loop -105.00 to 105.00 % 0.00% b5
132 RW SETPT. RATIO SERIAL LINKS::SYSTEM PORT (P3)::P3 SETĆ
UP::5703 SUPPORT
5703 -3.0000 to 3.0000 0.0000 do
133 RW SETPT. SIGN SERIAL LINKS::SYSTEM PORT (P3)::P3 SETĆ
UP::5703 SUPPORT
5703 0 : Negative 1 : Positive Positive dp
292 RW SIGN 0 SETUP PARAMETERS::SETPOINT SUM 1 Setpoint Sum 1 0 : Negative 1 : Positive Positive i4
8 RW Sign 1 SETUP PARAMETERS::SETPOINT SUM 1 Setpoint Sum 1 0 : Negative 1 : Positive Positive a8
9 RW Sign 2 (A3) SETUP PARAMETERS::SPEED LOOP::SETĆ
POINTS
Speed Loop 0 : Negative 1 : Positive Positive a9
97 RW Source Tag SYSTEM::CONFIGURE I/O::DIGITAL OUTĆ
PUTS::DIGOUT 1 (B5)
Digout 1 (B5) 0 to 549 77 cp 2, 3
98 RW Source Tag SYSTEM::CONFIGURE I/O::DIGITAL OUTĆ
PUTS::DIGOUT 2 (B6)
Digout 2 (B6) 0 to 549 122 cq 2, 3
99 RW Source Tag SYSTEM::CONFIGURE I/O::DIGITAL OUTĆ
PUTS::DIGOUT 3 (B7)
Digout 3 (B7) 0 to 549 125 cr 2, 3
134 RW Source Tag SYSTEM::CONFIGURE I/O::CONFIGURE 5703 5703 0 to 549 89 dq 2, 3
251 RW Source Tag SYSTEM::CONFIGURE I/O::ANALOG OUTĆ
PUTS::ANOUT 1 (A7)
Analog Output 1 0 to 549 62 gz 2, 3
252 RW Source Tag SYSTEM::CONFIGURE I/O::ANALOG OUTĆ
PUTS::ANOUT 2 (A8)
Analog Output 2 0 to 549 63 h0 2, 3
306 RW Source Tag SETUP PARAMETERS::STANDSTILL Standstill 0 to 549 89 ii 2, 3, 4
364 RW Source Tag SYSTEM::CONFIGURE I/O::INTERNAL
LINKS::LINK 1
Link 1 0 to 549 0 k4 2, 3
366 RW Source Tag SYSTEM::CONFIGURE I/O::INTERNAL
LINKS::LINK 2
Link 2 0 to 549 0 k6 2, 3
368 RW Source Tag SYSTEM::CONFIGURE I/O::INTERNAL
LINKS::LINK 3
Link 3 0 to 549 0 k8 2, 3
370 RW Source Tag SYSTEM::CONFIGURE I/O::INTERNAL
LINKS::LINK 4
Link 4 0 to 549 0 ka 2, 3
454 RW Source Tag SYSTEM::CONFIGURE I/O::INTERNAL
LINKS::LINK 5
Link 5 0 to 549 0 m
m
2, 3
456 RW Source Tag SYSTEM::CONFIGURE I/O::INTERNAL
LINKS::LINK 6
Link 6 0 to 549 0 mo 2, 3
458 RW Source Tag SYSTEM::CONFIGURE I/O::INTERNAL
LINKS::LINK 7
Link 7 0 to 549 0 mq 2, 3
460 RW Source Tag SYSTEM::CONFIGURE I/O::INTERNAL
LINKS::LINK 8
Link 8 0 to 549 0 ms 2, 3
467 RW Source Tag SYSTEM::CONFIGURE I/O::INTERNAL
LINKS::LINK 9
Link 9 0 to 549 0 mz 2, 3
469 RW Source Tag SYSTEM::CONFIGURE I/O::INTERNAL
LINKS::LINK 10
Link 10 0 to 549 0 n1 2, 3
32 RW SPD BRK1 (LOW) SETUP PARAMETERS::CURRENT PROFILE Current Profile 0.00 to 100.00 % (h) 100.00% aw 2