Baldor mn792 Universal Remote User Manual


 
Switch Setting & Start-Up 5-5MN792
Power up in Remote Mode with Feedback This procedure assumes that the terminal strip (connectors A, B C) are wired
according to the instructions provided in Section 4 and the feedback device is properly installed. (The start up
mode is defined by Parameter [517] =False for remote operation which is the same as SETUP
PARAMETERS::OP STATION::START UP VALUES::LOCAL = FALSE.)
When preoperation checks are complete, logic power can be applied to setup the software parameters. At this
point, 3 phase power should remain off, if possible.
1. Apply Logic power.
2. Verify the keypad and LEDs display correctly. If not, verify that the logic wiring is correct.
Action Description Display Comments
Apply Logic Power Keypad Display shows this opening
message.
BALDOR DC DRIVE
CALIBRATING
LEDs are flashing. After several
seconds the next screen is displayed.
The local mode (keypad mode) is
displayed
FORWARD
REF: 0.00%
The OK, SEQ, REF, FWD and STOP
LEDs are on.
3. Set the parameter Configure Enable to Enabled.
Action Description Display Comments
Apply Logic Power Keypad Display shows this opening
message.
FORWARD
REF: 0.00%
LEDs are flashing. After several
seconds the next screen is displayed.
Press PROG key
BALDOR DC DRIVE
DC 4Q 35A
Press M key
DC 4Q 35A
MENU LEVEL
Press M key Access the menus.
MENU LEVEL
DIAGNOSTICS
Press Y
Scroll to Configure Drive menu.
MENU LEVEL
CONFIGURE DRIVE
Press M key Access Configure Drive menu.
CONFIGURE DRIVE
CONFIGURE ENABLE
Press M key Access the Configure Enable
parameter.
CONFIGURE ENABLE
DISABLED
Press Y
Enable Configure Enable.
CONFIGURE ENABLE
ENABLED
All LEDs are now flashing.
Press E when done.
Press E key Returns to previous menu level.
CONFIGURE DRIVE
CONFIGURE ENABLE
4. Set the Nominal Motor Volts (Armature Voltage).
Action Description Display Comments
Press B
Scroll to the NOM Motor volts
parameter.
CONFIGURE DRIVE
CONFIGURE ENABLE
Press M key Access the NOM Motor Volts
parameter
CONFIGURE DRIVE
NOM MOTOR VOLTS
Press PROG key
NOM MOTOR VOLTS
180 VOLTS
Press Y to change to current control if
desired. Press E when done.