B-8 Parameter Table MN792
Table B-1 Parameters Listed by Tag Number Continued
Tag R/W Name Keypad Menu WB Block Range Factory Setting MN Notes
468 RW Destination Tag SYSTEM::CONFIGURE I/O::INTERNAL
LINKS::LINK 9
Link 9 0 to 549 0 n0 2, 3
469 RW Source Tag SYSTEM::CONFIGURE I/O::INTERNAL
LINKS::LINK 10
Link 10 0 to 549 0 n1 2, 3
470 RW Destination Tag SYSTEM::CONFIGURE I/O::INTERNAL
LINKS::LINK 10
Link 10 0 to 549 0 n2 2, 3
472 RO SPEED FBK STATE ALARM STATUS Unallocated 0 : False 1 : True False n4 Output
473 RW Mode SETUP PARAMETERS::SPECIAL BLOCKS::PID PID 0 to 4 0 n5
474 RW MIN PROFILE GAIN SETUP PARAMETERS::SPECIAL BLOCKS::PID PID 0.00 to 100.00 % 20.00% n6
475 RO Profiled Gain SETUP PARAMETERS::SPECIAL BLOCKS::PID PID xxxx.x 0.0 n7 Output
493 RO Output SYSTEM::CONFIGURE I/O::ANALOG INĆ
PUTS::ANIN 2 (A3)
Analog Input 2 xxx.xx % 0.00% np Output, 2
494 RW Destination Tag SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGITAL INPUT C4
Dig in C4 0 to 549 496 nq 2, 3
495 RW Destination Tag SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGITAL INPUT C5
Dig in C5 0 to 549 497 nr 2, 3
496 RO Jog/Slack SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On Off ns Output
497 RO Enable SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On On nt Output
500 RW TEC Option Type SERIAL LINKS::TEC OPTION Tec Option 0 : None
1 : Rs485
2 : Profibus Dp
3 : Link
4 : Device Net
5 : Can Open
6 : Lonworks
7 : Type 7
None nw
501 RW TEC Option IN 1 SERIAL LINKS::TEC OPTION Tec Option -32768 to 32767 0 nx
502 RW TEC Option IN 2 SERIAL LINKS::TEC OPTION Tec Option -32768 to 32767 0 ny
503 RW TEC Option IN 3 SERIAL LINKS::TEC OPTION Tec Option -32768 to 32767 0 nz
504 RW TEC Option IN 4 SERIAL LINKS::TEC OPTION Tec Option -32768 to 32767 0 o0
505 RW TEC Option IN 5 SERIAL LINKS::TEC OPTION Tec Option -32768 to 32767 0 o1
506 RO TEC Option Fault SERIAL LINKS::TEC OPTION Tec Option 0 : None
1 : Parameter
2 : Type Mismatch
3 : Self Test
4 : Hardware
5 : Missing
None o2 Output
507 RO TEC Option VER SERIAL LINKS::TEC OPTION Tec Option 0x0000 to 0xFFFF 0x0000 o3 Output, 1
508 RO TEC Option OUT 1 SERIAL LINKS::TEC OPTION Tec Option xxxxx 0 o4 Output, 1
509 RO TEC Option OUT 2 SERIAL LINKS::TEC OPTION Tec Option xxxxx 0 o5 Output, 1
511 RW Local Key Enable SETUP PARAMETERS::OP STATION::SET UP Op Station 0 : False 1 : True TRUE o7
512 RW Setpoint SETUP PARAMETERS::OP STATION::SET UP Op Station 0.00 to 100.00 % 0.00% o8 1
513 RW Jog Setpoint SETUP PARAMETERS::OP STATION::SET UP Op Station 0.00 to 100.00 % 5.00% o9 1
514 RW Ramp Accel Time SETUP PARAMETERS::OP STATION::LOCAL
RAMP
Op Station 0.1 to 600.0 Secs 10.0 Secs oa
515 RW Ramp Decel Time SETUP PARAMETERS::OP STATION::LOCAL
RAMP
Op Station 0.1 to 600.0 Secs 10.0 Secs ob
516 RW Forward SETUP PARAMETERS::OP STATION::START
UP VALUES
Op Station 0 : False 1 : True TRUE oc
517 RW Local SETUP PARAMETERS::OP STATION::START
UP VALUES
Op Station 0 : False 1 : True TRUE od
518 RW Program SETUP PARAMETERS::OP STATION::START
UP VALUES
Op Station 0 : False 1 : True FALSE oe
519 RW Setpoint SETUP PARAMETERS::OP STATION::START
UP VALUES
Op Station 0.00 to 100.00 % 0.00% of
520 RW Jog Setpoint SETUP PARAMETERS::OP STATION::START
UP VALUES
Op Station 0.00 to 100.00 % 5.00% og
521 RW NOM Motor Volts CONFIGURE DRIVE Calibration 100 to 875 Volts 500 Volts oh 3
523 RW Armature Current CONFIGURE DRIVE Calibration 2.0 to 15.0 AMPS 2.0 Amps oj 3
524 RW Field Current CONFIGURE DRIVE Calibration 0.2 to 4.0 AMPS 0.2 Amps ok 3
525 RO Coast Stop DIAGNOSTICS Stop Rates 0 : False 1 : True FALSE ol Output
527 RO Master Bridge SETUP PARAMETERS::CURRENT LOOP Current Loop 0 : Off 1 : On Off on Output, 1