Baldor mn792 Universal Remote User Manual


 
B-30 Parameter Table MN792
Table B-4 Parameters Listed by WB Block Continued
Tag R/W Name Keypad Menu WB Block Range Factory Setting MN Notes
464 RW Offset SYSTEM::CONFIGURE I/O::ANALOG OUTĆ
PUTS::ANOUT 1 (A7)
Analog Output 1 -100.00 to 100.00 % 0.00% mw
251 RW Source Tag SYSTEM::CONFIGURE I/O::ANALOG OUTĆ
PUTS::ANOUT 1 (A7)
Analog Output 1 0 to 549 62 gz 2, 3
56 RO ANOUT 2 (A8) DIAGNOSTICS Analog Output 2 xxx.xx VOLTS (h) 0.00V bk Output
248 RW % TO GET 10V SYSTEM::CONFIGURE I/O::ANALOG OUTĆ
PUTS::ANOUT 2 (A8)
Analog Output 2 -300.00 to 300.00 % 100.00% gw
363 RW Modulus SYSTEM::CONFIGURE I/O::ANALOG OUTĆ
PUTS::ANOUT 2 (A8)
Analog Output 2 0 : False 1 : True FALSE k3
465 RW Offset SYSTEM::CONFIGURE I/O::ANALOG OUTĆ
PUTS::ANOUT 2 (A8)
Analog Output 2 -100.00 to 100.00 % 0.00% mx
252 RW Source Tag SYSTEM::CONFIGURE I/O::ANALOG OUTĆ
PUTS::ANOUT 2 (A8)
Analog Output 2 0 to 549 63 h0 2, 3
69 RO Digital Input C4 DIAGNOSTICS Aux I/O 0 : Off 1 : On Off bx Output
70 RO Digital Input C5 DIAGNOSTICS Aux I/O 0 : Off 1 : On On by Output
68 RO Start (C3) DIAGNOSTICS Aux I/O 0 : Off 1 : On Off bw Output
128 RW ANOUT 1 SETUP PARAMETERS::AUX I/O Aux I/O -100.00 to 100.00 % 0.00% dk
129 RW ANOUT 2 SETUP PARAMETERS::AUX I/O Aux I/O -100.00 to 100.00 % 0.00% dl
94 RW AUX DIGOUT 1 SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On Off cm
95 RW AUX DIGOUT 2 SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On Off cn
96 RW AUX DIGOUT 3 SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On Off co
168 RW Aux Enable SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On On eo
227 RW AUX JOG SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On On gb
161 RW AUX START SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On On eh
497 RO Enable SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On On nt Output
496 RO Jog/Slack SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On Off ns Output
535 RW REM.SEQ.ENABLE SETUP PARAMETERS::AUX I/O Aux I/O 0 : False, 1 : True FALSE ov 2
536 RW REM.SEQUENCE SETUP PARAMETERS::AUX I/O Aux I/O 0x0000 to 0xFFFF 0x0000 ow 1
537 RO SEQ Status SETUP PARAMETERS::AUX I/O Aux I/O 0x0000 to 0xFFFF 0x0C03 ox Output
523 RW Armature Current CONFIGURE DRIVE Calibration 2.0 to 15.0 AMPS 2.0 Amps oj 3
24 RW Encoder Lines CONFIGURE DRIVE Calibration 10 to 5000 1024 ao 2
22 RW Encoder RPM CONFIGURE DRIVE Calibration 0 to 6000 RPM 1750 RPM am
524 RW Field Current CONFIGURE DRIVE Calibration 0.2 to 4.0 AMPS 0.2 Amps ok 3
521 RW NOM Motor Volts CONFIGURE DRIVE Calibration 100 to 875 Volts 500 Volts oh 3
60 RO BACK EMF DIAGNOSTICS Calibration xxx.xx % (h) 0.0% bo Output
57 RO Terminal Volts DIAGNOSTICS Calibration xxx.xx % (h) 0.0% bl Output
181 RO Unfil. Field FBK DIAGNOSTICS Calibration xxx.xx % 0.00% f1 Output
59 RO UNFIL.ENCODER DIAGNOSTICS Calibration xxxxx RPM 0 RPM bn Output
58 RO UNFIL.TACH INPUT DIAGNOSTICS Calibration xxx.xx % (h) 0.0% bm Output
23 RW Analog TACH CAL SETUP PARAMETERS::CALIBRATION Calibration 0.9800 to 1.1000 1.0000 an
25 RW Armature I (A9) SETUP PARAMETERS::CALIBRATION Calibration 0 : UNIPOLAR
1 : BIPOLAR
Bipolar ap
20 RW Armature V CAL. SETUP PARAMETERS::CALIBRATION Calibration 0.9800 to 1.1000 1.0000 ak
182 RW Field I CAL. SETUP PARAMETERS::CALIBRATION Calibration 0.9800 to 1.1000 1.0000 f2
21 RW IR Compensation SETUP PARAMETERS::CALIBRATION Calibration 0.00 to 100.00 % 0.00% al
188 RW Over Speed Level SETUP PARAMETERS::CALIBRATION Calibration 0.00 to 200.00 % 125.00% f8 4
180 RW SPDFBK ALM LEVEL SETUP PARAMETERS::CALIBRATION Calibration 0.00 to 100.00 % (h) 50.00% f0
263 RW Stall Threshold SETUP PARAMETERS::CALIBRATION Calibration 0.00 to 200.00 % 95.00% hb
224 RW Stall Trip Delay SETUP PARAMETERS::CALIBRATION Calibration 0.1 to 600.0 Secs 10.0 Secs g8
10 RW Zero SPD. Offset SETUP PARAMETERS::CALIBRATION Calibration -5.00 to 5.00 % 0.00% aa
18 RO Autotune CONFIGURE DRIVE Current Loop 0 : Off 1 : On Off ai Output, 1
15 RW CUR.LIMIT/SCALER CONFIGURE DRIVE Current Loop 0.00 to 200.00 % 90.00% af
42 RO At Current Limit DIAGNOSTICS Current Loop 0 : False 1 : True False b6 Output
538 RO Current FBK.Amps DIAGNOSTICS Current Loop xxxx.x AMPS 0.0 Amps oy Output, 1, 3
539 RO Field I FBK.AMPS DIAGNOSTICS Current Loop xxxx.x AMPS 0.0 Amps oz Output, 1, 3
66 RO IaDmd UNFILTERED DIAGNOSTICS Current Loop xxx.xx % (h) 0.0% bu Output
65 RO IaFbk UNFILTERED DIAGNOSTICS Current Loop xxx.xx % (h) 0.0% bt Output
30 RW Additional DEM SETUP PARAMETERS::CURRENT LOOP Current Loop -200.00 to 200.00 % 0.00% au
90 RW Bipolar Clamps SETUP PARAMETERS::CURRENT LOOP Current Loop 0 : Disabled 1 : Enabled Disabled ci
137 RW Discontinuous SETUP PARAMETERS::CURRENT LOOP Current Loop 0.00 to 200.00 % 12.00% dt
136 RW Feed Forward SETUP PARAMETERS::CURRENT LOOP Current Loop 0.10 to 50.00 2.00 ds 4