Baldor mn792 Universal Remote User Manual


 
Quick Start 1-3MN792
Y and B scroll the menu choices, and M goes to next level menu and E comes back up one menu level.
Action Description Display Comments
Apply Power Keypad Display shows this opening
message.
FORWARD
REF: 0.00%
Local control display.
Press PROG key
BALDOR DC DRIVE
DC 4Q 15A
This message may be different for
each control size.
Press M key
DC 4Q 15A
MENU LEVEL
Press M key Access the menus.
MENU LEVEL
DIAGNOSTICS
Press Y
Scroll to Configure Drive menu.
MENU LEVEL
CONFIGURE DRIVE
Press M key Access the Configure Drive Menu
CONFIGURE DRIVE
CONFIGURE ENABLE
Press M twice to go down 2 menu
levels
Press M key Access Configure Enable.
CONFIGURE ENABLE
DISABLED
Configure enable is disabled and
no parameter value can be
changed.
Press Y key
Change Disabled to Enabled.
CONFIGURE ENABLE
ENABLED
Configure enable must be enabled
to allow a change to any parameter
value. All LEDs on keypad are
blinking to show it is enabled.
Press E key Return to the Configure Drive Menu
CONFIGURE DRIVE
CONFIGURE ENABLE
Press B
Set the motor volts.
NOM MOTOR VOLTS
Use up and down arrows to set the
motor voltage.
Press B
Set the armature current.
ARMATURE CURRENT
Use up and down arrows to set.
Press E when done.
Press B
Set the field current (skip if field is
in voltage mode.
FIELD CURRENT
Use up and down arrows to set.
Press E when done.
Press B
Set the field control mode (voltage
or current).
FLD. CTRL MODE
Use up and down arrows to set.
Press E when done.
Press B
Field Volts Ratio=
(field volts/AC supply)*100
FLD. VOLTS RATIO
Use up and down arrows to set.
Press E when done.
Press B
Set the current limit
(normally 100%).
MAIN CURR. LIMIT
Use up and down arrows to set.
Press E when done.
Press B
Leave autotune off.
AUTOTUNE
Autotune after calibration is
complete.
Press B
Select Armature Volts, Analog
TACH or Encoder.
SPEED FBK SELECT
Use up and down arrows to set.
Press E when done.
Press B
Set the pulses per REV of the
encoder.
ENCODER LINES
Use up and down arrows to set.
Press E when done.
Press B
Set the encoder max speed (100%
speed).
ENCODER RPM
Use up and down arrows to set.
Press E when done.
Press B
Change the polarity of the encoder
signal if needed.
ENCODER SIGN
Use up and down arrows to set.
Press E when done.
Press B
The Speed Loop Integral Gain.
SPD INT TIME
Use up and down arrows to set.
Press E when done.
Press B
The Speed Loop Proportional Gain.
SPEED PROP GAIN
Use up and down arrows to set.
Press E when done.