Baldor mn792 Universal Remote User Manual


 
B-2 Parameter Table MN792
Table B-1 Parameters Listed by Tag Number Continued
Tag R/W Name Keypad Menu WB Block Range Factory Setting MN Notes
53 RO ANIN 4 (A5) DIAGNOSTICS Analog Input 4 xxx.xx VOLTS 0.00V bh Output
54 RO ANIN 5 (A6) DIAGNOSTICS Analog Input 5 xxx.xx VOLTS 10.00V bi Output
55 RO ANOUT 1 (A7) DIAGNOSTICS Analog Output 1 xxx.xx VOLTS (h) 0.00V bj Output
56 RO ANOUT 2 (A8) DIAGNOSTICS Analog Output 2 xxx.xx VOLTS (h) 0.00V bk Output
57 RO Terminal Volts DIAGNOSTICS Calibration xxx.xx % (h) 0.0% bl Output
58 RO UNFIL.TACH INPUT DIAGNOSTICS Calibration xxx.xx % (h) 0.0% bm Output
59 RO UNFIL.ENCODER DIAGNOSTICS Calibration xxxxx RPM 0 RPM bn Output
60 RO BACK EMF DIAGNOSTICS Calibration xxx.xx % (h) 0.0% bo Output
61 RO ACTUAL NEG I LIM DIAGNOSTICS Diagnostics xxx.xx % (h) -90.0% bp Output
62 RO UNFIL.SPD.FBK DIAGNOSTICS Speed Loop xxx.xx % 0.03% bq Output
63 RO Speed Setpoint DIAGNOSTICS Speed Loop xxx.xx % 0.00% br Output
64 RO UNFIL.SPD.ERROR DIAGNOSTICS Speed Loop xxx.xx % 0.00% bs Output
65 RO IaFbk UNFILTERED DIAGNOSTICS Current Loop xxx.xx % (h) 0.0% bt Output
66 RO IaDmd UNFILTERED DIAGNOSTICS Current Loop xxx.xx % (h) 0.0% bu Output
67 RO ACTUAL POS I LIM DIAGNOSTICS Diagnostics xxx.xx % (h) 90.00% bv Output
68 RO Start (C3) DIAGNOSTICS Aux I/O 0 : Off 1 : On Off bw Output
69 RO Digital Input C4 DIAGNOSTICS Aux I/O 0 : Off 1 : On Off bx Output
70 RO Digital Input C5 DIAGNOSTICS Aux I/O 0 : Off 1 : On On by Output
71 RO DIGIN 1 (C6) DIAGNOSTICS Digital Input 1 0 : Off 1 : On Off bz Output
72 RO DIGIN 2 (C7) DIAGNOSTICS Digital Input 2 0 : Off 1 : On Off c0 Output
73 RO DIGIN 3 (C8) DIAGNOSTICS Digital Input 3 0 : Off 1 : On Off c1 Output
74 RO DIGOUT 1 (B5) DIAGNOSTICS Digout 1 (B5) 0 : Off 1 : On On c2 Output
75 RO DIGOUT 2 (B6) DIAGNOSTICS Digout 2 (B6) 0 : Off 1 : On On c3 Output
76 RO DIGOUT 3 (B7) DIAGNOSTICS Digout 3 (B7) 0 : Off 1 : On Off c4 Output
77 RO At Zero Speed DIAGNOSTICS Standstill 0 : False 1 : True True c5 Output
78 RO At Zero Setpoint DIAGNOSTICS Standstill 0 : False 1 : True True c6 Output
79 RO At Standstill DIAGNOSTICS Standstill 0 : False 1 : True True c7 Output
80 RO Program Stop DIAGNOSTICS Stop Rates 0 : False 1 : True False c8 Output
81 RW SPEED FBK ALARM SETUP PARAMETERS::INHIBIT ALARMS Alarms 0 : Enabled 1 : Inhibited Enabled c9
82 RO Drive Start DIAGNOSTICS Diagnostics 0 : Off 1 : On Off ca Output
83 RO Contactor Closed DIAGNOSTICS Unallocated 0 : Off 1 : On Off cb Output
84 RO Drive Enable DIAGNOSTICS Diagnostics 0 : Disabled 1 : Enabled Disabled cc Output
85 RO Ramp Output DIAGNOSTICS Ramps xxx.xx % 0.00% cd Output
86 RO SPT SUM OUTPUT DIAGNOSTICS Setpoint Sum 1 xxx.xx % 0.00% ce Output
87 RO POS. I CLAMP DIAGNOSTICS Diagnostics xxx.xx % (h) 90.0% cf Output
88 RO NEG. I CLAMP DIAGNOSTICS Diagnostics xxx.xx % (h) -90.0% cg Output
89 RO Speed Demand DIAGNOSTICS Stop Rates xxx.xx % 0.00% ch Output
90 RW Bipolar Clamps SETUP PARAMETERS::CURRENT LOOP Current Loop 0 : Disabled 1 : Enabled Disabled ci
91 RW PROG STOP I LIM SETUP PARAMETERS::STOP RATES Stop Rates 0.00 to 200.00 % 100.00% cj
92 RW Encoder Alarm SETUP PARAMETERS::INHIBIT ALARMS Alarms 0 : Enabled 1 : Inhibited Enabled ck
93 RW IMAX BRK1(SPD1) SETUP PARAMETERS::CURRENT PROFILE Current Profile 0.00 to 200.00 % (h) 200.00% cl 2
94 RW AUX DIGOUT 1 SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On Off cm
95 RW AUX DIGOUT 2 SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On Off cn
96 RW AUX DIGOUT 3 SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On Off co
97 RW Source Tag SYSTEM::CONFIGURE I/O::DIGITAL OUTĆ
PUTS::DIGOUT 1 (B5)
Digout 1 (B5) 0 to 549 77 cp 2, 3
98 RW Source Tag SYSTEM::CONFIGURE I/O::DIGITAL OUTĆ
PUTS::DIGOUT 2 (B6)
Digout 2 (B6) 0 to 549 122 cq 2, 3
99 RW Source Tag SYSTEM::CONFIGURE I/O::DIGITAL OUTĆ
PUTS::DIGOUT 3 (B7)
Digout 3 (B7) 0 to 549 125 cr 2, 3
100 RW Input 1 SETUP PARAMETERS::SETPOINT SUM 1 Setpoint Sum 1 -200.00 to 200.00 % 0.00% cs
102 RW Destination Tag SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 1 (C6)
Digital Input 1 0 to 549 90 cu 2, 3
103 RW Value For True SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 1 (C6)
Digital Input 1 -300.00 to 300.00 % 0.01% cv
104 RW Value For False SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 1 (C6)
Digital Input 1 -300.00 to 300.00 % 0.00% cw
105 RW Destination Tag SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 2 (C7)
Digital Input 2 0 to 549 118 cx 2, 3
106 RW Value For True SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 2 (C7)
Digital Input 2 -300.00 to 300.00 % 0.01% cy