Parameter Table B-15MN792
Table B-2 Parameters Listed by Name Continued
Tag R/W Name Keypad Menu WB Block Range Factory Setting MN Notes
493 RO Output SYSTEM::CONFIGURE I/O::ANALOG INĆ
PUTS::ANIN 2 (A3)
Analog Input 2 xxx.xx % 0.00% np Output, 2
188 RW Over Speed Level SETUP PARAMETERS::CALIBRATION Calibration 0.00 to 200.00 % 125.00% f8 4
198 RW P3 Baud Rate SERIAL LINKS::SYSTEM PORT (P3)::P3 SETĆ
UP
0:300 1:600 2:1200
3:2400 4:4800 5:9600
6:19200
9600 fi 2
354 RW Parameter Save PARAMETER SAVE Unallocated Up To Action Requested ju 1
123 RW Peek Data SYSTEM::PEEK 0x0000 to 0xFFFF 0x0078 df
124 RW Peek Scale SYSTEM::PEEK -300.00 to 300.00 8.00 dg
416 RO PID Clamped DIAGNOSTICS PID 0 : False 1 : True False lk Output
415 RO PID Error DIAGNOSTICS PID xxx.xx % 0.00% lj Output
400 RW PID O/P DEST SYSTEM::CONFIGURE I/O::BLOCK DIAGRAM PID Output 0 to 549 0 l4 2, 3
417 RO PID Output DIAGNOSTICS PID xxx.xx % 0.00% ll Output
87 RO POS. I CLAMP DIAGNOSTICS Diagnostics xxx.xx % (h) 90.0% cf Output
301 RW POS. I CLAMP SETUP PARAMETERS::CURRENT LOOP Current Loop -100.00 to 100.00 % 100.00% id
273 RW POS. LOOP P GAIN SETUP PARAMETERS::SPEED LOOP::ADĆ
VANCED
Advanced -200.00 to 200.00 % 0.00% hl 4
405 RW Positive Limit SETUP PARAMETERS::SPECIAL BLOCKS::PID PID 0.00 to 105.00 % 100.00% l9
475 RO Profiled Gain SETUP PARAMETERS::SPECIAL BLOCKS::PID PID xxxx.x 0.0 n7 Output
91 RW PROG STOP I LIM SETUP PARAMETERS::STOP RATES Stop Rates 0.00 to 200.00 % 100.00% cj
216 RW PROG STOP LIMIT SETUP PARAMETERS::STOP RATES Stop Rates 0.0 to 600.0 Secs 60.0 Secs g0
26 RW PROG Stop Time SETUP PARAMETERS::STOP RATES Stop Rates 0.1 to 600.0 Secs 0.1 Secs aq
518 RW Program SETUP PARAMETERS::OP STATION::START
UP VALUES
Op Station 0 : False 1 : True FALSE oe
80 RO Program Stop DIAGNOSTICS Stop Rates 0 : False 1 : True False c8 Output
16 RW PROP. GAIN SETUP PARAMETERS::CURRENT LOOP Current Loop 0.00 to 200.00 45.00 ag
173 RW PROP. GAIN SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS
Field Control 0.00 to 100.00 0.10 et
271 RW PROP. GAIN SETUP PARAMETERS::SPEED LOOP::ADĆ
VANCED::ADAPTION
Advanced 0.00 to 200.00 5.00 hj
404 RW PROP. GAIN SETUP PARAMETERS::SPECIAL BLOCKS::PID PID 0.0 to 100.0 1.0 l8
261 RW Raise Input SETUP PARAMETERS::RAISE/LOWER Raise/Lower 0 : False 1 : True FALSE h9
260 RW Raise/Lower Dest SYSTEM::CONFIGURE I/O::BLOCK DIAGRAM Raise/Lower
Output
0 to 549 0 h8
264 RO Raise/Lower O/P DIAGNOSTICS Raise/Lower xxx.xx % 0.00% hc Output
2 RW Ramp Accel Time SETUP PARAMETERS::RAMPS Ramps 0.1 to 600.0 Secs 10.0 Secs a2
514 RW Ramp Accel Time SETUP PARAMETERS::OP STATION::LOCAL
RAMP
Op Station 0.1 to 600.0 Secs 10.0 Secs oa
3 RW Ramp Decel Time SETUP PARAMETERS::RAMPS Ramps 0.1 to 600.0 Secs 10.0 Secs a3
515 RW Ramp Decel Time SETUP PARAMETERS::OP STATION::LOCAL
RAMP
Op Station 0.1 to 600.0 Secs 10.0 Secs ob
118 RW Ramp Hold SETUP PARAMETERS::RAMPS Ramps 0 : Off 1 : On Off da
5 RW Ramp Input SETUP PARAMETERS::RAMPS Ramps -105.00 to 105.00 % 0.00% a5
293 RW RAMP O/P DEST SYSTEM::CONFIGURE I/O::BLOCK DIAGRAM Ramp Output 0 to 549 291 i5 2, 3
85 RO Ramp Output DIAGNOSTICS Ramps xxx.xx % 0.00% cd Output
355 RW Ramp Rate SETUP PARAMETERS::JOG/SLACK Jog/Slack 0.1 to 600.0 Secs 1.0 Secs jv
113 RO Ramping DIAGNOSTICS Ramps 0 : False 1 : True False d5 Output
286 RW RAMPING THRESH. SETUP PARAMETERS::RAMPS Ramps 0.00 to 100.00 % 0.50% hy
200 RW Rate SETUP PARAMETERS::INVERSE TIME Inverse Time 0.1 to 600.0 Secs 60.0 Secs fk 2, 4
208 RW Ratio 0 SETUP PARAMETERS::SETPOINT SUM 1 Setpoint Sum 1 -3.0000 to 3.0000 1.0000 fs
6 RW Ratio 1 SETUP PARAMETERS::SETPOINT SUM 1 Setpoint Sum 1 -3.0000 to 3.0000 1.0000 a6
412 RW Ratio 1 SETUP PARAMETERS::SPECIAL BLOCKS::PID PID -3.0000 to 3.0000 1.0000 lg
413 RW Ratio 2 SETUP PARAMETERS::SPECIAL BLOCKS::PID PID -3.0000 to 3.0000 1.0000 lh
7 RW Ratio 2 (A3) SETUP PARAMETERS::SPEED LOOP::SETĆ
POINTS
Speed Loop -3.0000 to 3.0000 .0000 a7
187 RO Raw Input SERIAL LINKS::SYSTEM PORT (P3)::P3 SETĆ
UP::5703 SUPPORT
5703 xxx.xx % 0.00% f7 Output
125 RO Ready DIAGNOSTICS Alarms 0 : False 1 : True False dh Output
201 RW Regen Mode SETUP PARAMETERS::CURRENT LOOP Current Loop 0 : 2Q (Non-regen)
1 : 4Q (Regen)
2Q(Non-regen) fl 2
541 RW REM Trip Delay SETUP PARAMETERS::CALIBRATION Alarms 0.1 to 600.0 Secs 10.0 Secs p1