Baldor mn792 Universal Remote User Manual


 
Parameter Table B-3MN792
Table B-1 Parameters Listed by Tag Number Continued
Tag R/W Name Keypad Menu WB Block Range Factory Setting MN Notes
107 RW Value For False SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 2 (C7)
Digital Input 2 -300.00 to 300.00 % 0.00% cz
108 RW Destination Tag SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 3 (C8)
Digital Input 3 0 to 549 119 d0 2, 3
109 RW Value For True SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 3 (C8)
Digital Input 3 -300.00 to 300.00 % 0.01% d1
110 RW Value For False SYSTEM::CONFIGURE I/O::DIGITAL INĆ
PUTS::DIGIN 3 (C8)
Digital Input 3 -300.00 to 300.00 % 0.00% d2
111 RW 5703 RCV ERROR SETUP PARAMETERS::INHIBIT ALARMS Alarms 0 : Enabled 1 : Inhibited Enabled d3
112 RO Stall Trip ALARM STATUS Alarms 0 : OK 1 : Failed OK d4 Output
113 RO Ramping DIAGNOSTICS Ramps 0 : False 1 : True False d5 Output
115 RO Health Word ALARM STATUS Alarms 0x0000 to 0xFFFF 0x0200 d7 Output
116 RO Health Store ALARM STATUS Alarms 0x0000 to 0xFFFF 0x0000 d8 Output
118 RW Ramp Hold SETUP PARAMETERS::RAMPS Ramps 0 : Off 1 : On Off da
119 RW I DMD. ISOLATE SETUP PARAMETERS::CURRENT LOOP Current Loop 0 : Disabled 1 : Enabled Disabled db
120 RW Enter Password PASSWORD 0x0000 to 0xFFFF 0x0000 dc 1
121 RW Change Password PASSWORD 0x0000 to 0xFFFF 0x0000 dd
122 RO Health LED DIAGNOSTICS Alarms 0 : False 1 : True True de Output
123 RW Peek Data SYSTEM::PEEK 0x0000 to 0xFFFF 0x0078 df
124 RW Peek Scale SYSTEM::PEEK -300.00 to 300.00 8.00 dg
125 RO Ready DIAGNOSTICS Alarms 0 : False 1 : True False dh Output
126 RW MIN SPEED SETUP PARAMETERS::RAMPS Ramps 0.00 to 100.00 % 0.00% di
128 RW ANOUT 1 SETUP PARAMETERS::AUX I/O Aux I/O -100.00 to 100.00 % 0.00% dk
129 RW ANOUT 2 SETUP PARAMETERS::AUX I/O Aux I/O -100.00 to 100.00 % 0.00% dl
130 RW Mode SERIAL LINKS::SYSTEM PORT (P3)::P3 SETĆ
UP
System Port P3 0 : Disabled
1 : 5703 Master
2 : 5703 Slave
3 : CELite (EIASCII)
0 dm
131 RW Deadband Width SETUP PARAMETERS::SETPOINT SUM 1 Setpoint Sum 1 0.00 to 100.00 % (h) 0.0% dn
132 RW SETPT. RATIO SERIAL LINKS::SYSTEM PORT (P3)::P3 SETĆ
UP::5703 SUPPORT
5703 -3.0000 to 3.0000 0.0000 do
133 RW SETPT. SIGN SERIAL LINKS::SYSTEM PORT (P3)::P3 SETĆ
UP::5703 SUPPORT
5703 0 : Negative 1 : Positive Positive dp
134 RW Source Tag SYSTEM::CONFIGURE I/O::CONFIGURE 5703 5703 0 to 549 89 dq 2, 3
135 RW Destination Tag SYSTEM::CONFIGURE I/O::CONFIGURE 5703 Scaled 5703 InĆ
put
0 to 549 41 dr 2, 3
136 RW Feed Forward SETUP PARAMETERS::CURRENT LOOP Current Loop 0.10 to 50.00 2.00 ds 4
137 RW Discontinuous SETUP PARAMETERS::CURRENT LOOP Current Loop 0.00 to 200.00 % 12.00% dt
155 RO Version Number SERIAL LINKS::SYSTEM PORT (P3) Unallocated 0x0000 to 0xFFFF eb Output
161 RW AUX START SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On On eh
168 RW Aux Enable SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On On eo
169 RO Field Enabled DIAGNOSTICS Field Control 0 : Disabled 1 : Enabled Disabled ep Output
170 RW Field Enable SETUP PARAMETERS::FIELD CONTROL Field Control 0 : Disabled 1 : Enabled Enabled eq 2
171 RW Setpoint SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS
Field Control 0.00 to 100.00 % 100.00% er
172 RW INT. GAIN SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS
Field Control 0.00 to 100.00 1.28 es
173 RW PROP. GAIN SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS
Field Control 0.00 to 100.00 0.10 et
174 RW FLD. WEAK ENABLE SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS::FLD.WEAK VARS
Field Control 0 : Disabled 1 : Enabled Disabled eu 2
175 RW EMF LEAD SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS::FLD.WEAK VARS
Field Control 0.10 to 50.00 2.00 ev
176 RW EMF LAG SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS::FLD.WEAK VARS
Field Control 0.00 to 200.00 40.00 ew
177 RW EMF GAIN SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS::FLD.WEAK VARS
Field Control 0.00 to 100.00 0.30 ex
178 RW MAX VOLTS SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS::FLD.WEAK VARS
Field Control 0.00 to 100.00 % 100.00% ey
179 RW MIN FLD.CURRENT SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS::FLD.WEAK VARS
Field Control 0.00 to 100.00 % 10.00% ez 2
180 RW SPDFBK ALM LEVEL SETUP PARAMETERS::CALIBRATION Calibration 0.00 to 100.00 % (h) 50.00% f0