B-22 Parameter Table MN792
Table B-3 Parameters Listed by Keypad Menu Continued
Tag R/W Name Keypad Menu WB Block Range Factory Setting MN Notes
227 RW AUX JOG SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On On gb
161 RW AUX START SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On On eh
497 RO Enable SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On On nt Output
496 RO Jog/Slack SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On Off ns Output
535 RW REM.SEQ.ENABLE SETUP PARAMETERS::AUX I/O Aux I/O 0 : False, 1 : True FALSE ov 2
536 RW REM.SEQUENCE SETUP PARAMETERS::AUX I/O Aux I/O 0x0000 to 0xFFFF 0x0000 ow 1
537 RO SEQ Status SETUP PARAMETERS::AUX I/O Aux I/O 0x0000 to 0xFFFF 0x0C03 ox Output
23 RW Analog TACH CAL SETUP PARAMETERS::CALIBRATION Calibration 0.9800 to 1.1000 1.0000 an
25 RW Armature I (A9) SETUP PARAMETERS::CALIBRATION Calibration 0 : UNIPOLAR
1 : BIPOLAR
Bipolar ap
20 RW Armature V CAL. SETUP PARAMETERS::CALIBRATION Calibration 0.9800 to 1.1000 1.0000 ak
182 RW Field I CAL. SETUP PARAMETERS::CALIBRATION Calibration 0.9800 to 1.1000 1.0000 f2
21 RW IR Compensation SETUP PARAMETERS::CALIBRATION Calibration 0.00 to 100.00 % 0.00% al
188 RW Over Speed Level SETUP PARAMETERS::CALIBRATION Calibration 0.00 to 200.00 % 125.00% f8 4
541 RW REM Trip Delay SETUP PARAMETERS::CALIBRATION Alarms 0.1 to 600.0 Secs 10.0 Secs p1
180 RW SPDFBK ALM LEVEL SETUP PARAMETERS::CALIBRATION Calibration 0.00 to 100.00 % (h) 50.00% f0
263 RW Stall Threshold SETUP PARAMETERS::CALIBRATION Calibration 0.00 to 200.00 % 95.00% hb
224 RW Stall Trip Delay SETUP PARAMETERS::CALIBRATION Calibration 0.1 to 600.0 Secs 10.0 Secs g8
10 RW Zero SPD. Offset SETUP PARAMETERS::CALIBRATION Calibration -5.00 to 5.00 % 0.00% aa
30 RW Additional DEM SETUP PARAMETERS::CURRENT LOOP Current Loop -200.00 to 200.00 % 0.00% au
90 RW Bipolar Clamps SETUP PARAMETERS::CURRENT LOOP Current Loop 0 : Disabled 1 : Enabled Disabled ci
137 RW Discontinuous SETUP PARAMETERS::CURRENT LOOP Current Loop 0.00 to 200.00 % 12.00% dt
136 RW Feed Forward SETUP PARAMETERS::CURRENT LOOP Current Loop 0.10 to 50.00 2.00 ds 4
119 RW I DMD. ISOLATE SETUP PARAMETERS::CURRENT LOOP Current Loop 0 : Disabled 1 : Enabled Disabled db
17 RW INT. GAIN SETUP PARAMETERS::CURRENT LOOP Current Loop 0.00 to 200.00 3.50 ah
421 RW MAIN CURR. LIMIT SETUP PARAMETERS::CURRENT LOOP Current Loop 0.00 to 200.00 % 200.00% lp
527 RO Master Bridge SETUP PARAMETERS::CURRENT LOOP Current Loop 0 : Off 1 : On Off on Output, 1
48 RW NEG. I CLAMP SETUP PARAMETERS::CURRENT LOOP Current Loop -100.00 to 100.00 % 0.00% bc
301 RW POS. I CLAMP SETUP PARAMETERS::CURRENT LOOP Current Loop -100.00 to 100.00 % 100.00% id
16 RW PROP. GAIN SETUP PARAMETERS::CURRENT LOOP Current Loop 0.00 to 200.00 45.00 ag
201 RW Regen Mode SETUP PARAMETERS::CURRENT LOOP Current Loop 0 : 2Q (Non-regen)
1 : 4Q (Regen)
2Q(Non-regen) fl 2
93 RW IMAX BRK1(SPD1) SETUP PARAMETERS::CURRENT PROFILE Current Profile 0.00 to 200.00 % (h) 200.00% cl 2
33 RW IMAX BRK2(SPD2) SETUP PARAMETERS::CURRENT PROFILE Current Profile 0.00 to 200.00 % (h) 200.00% ax 2
32 RW SPD BRK1 (LOW) SETUP PARAMETERS::CURRENT PROFILE Current Profile 0.00 to 100.00 % (h) 100.00% aw 2
31 RW SPD BRK2 (HIGH) SETUP PARAMETERS::CURRENT PROFILE Current Profile 0.00 to 100.00 % (h) 100.00% av 2
170 RW Field Enable SETUP PARAMETERS::FIELD CONTROL Field Control 0 : Disabled 1 : Enabled Enabled eq 2
617 RW Field I Thresh SETUP PARAMETERS::FIELD CONTROL Field Control 0.00 to 100.00 % 80.00%
186 RW FLD. QUENCH
MODE
SETUP PARAMETERS::FIELD CONTROL Field Control 0 : Quench 1 : Standby Quench f6
185 RW FLD.QUENCH
DELAY
SETUP PARAMETERS::FIELD CONTROL Field Control 0.0 to 600.0 Secs 0.0 Secs f5
618 RO Up To Field SETUP PARAMETERS::FIELD CONTROL Field Control 0 : False 1 : True False Output
172 RW INT. GAIN SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS
Field Control 0.00 to 100.00 1.28 es
173 RW PROP. GAIN SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS
Field Control 0.00 to 100.00 0.10 et
171 RW Setpoint SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS
Field Control 0.00 to 100.00 % 100.00% er
192 RW BEMF FBK LAG SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS::FLD.WEAK VARS
Field Control 10 to 5000 100 fc
191 RW BEMF FBK LEAD SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS::FLD.WEAK VARS
Field Control 10 to 5000 100 fb
177 RW EMF GAIN SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS::FLD.WEAK VARS
Field Control 0.00 to 100.00 0.30 ex
176 RW EMF LAG SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS::FLD.WEAK VARS
Field Control 0.00 to 200.00 40.00 ew
175 RW EMF LEAD SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS::FLD.WEAK VARS
Field Control 0.10 to 50.00 2.00 ev
174 RW FLD. WEAK ENABLE SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS::FLD.WEAK VARS
Field Control 0 : Disabled 1 : Enabled Disabled eu 2