Baldor mn792 Universal Remote User Manual


 
Parameter Table B-23MN792
Table B-3 Parameters Listed by Keypad Menu Continued
Tag R/W Name Keypad Menu WB Block Range Factory Setting MN Notes
178 RW MAX VOLTS SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS::FLD.WEAK VARS
Field Control 0.00 to 100.00 % 100.00% ey
179 RW MIN FLD.CURRENT SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS::FLD.WEAK VARS
Field Control 0.00 to 100.00 % 10.00% ez 2
111 RW 5703 RCV ERROR SETUP PARAMETERS::INHIBIT ALARMS Alarms 0 : Enabled 1 : Inhibited Enabled d3
92 RW Encoder Alarm SETUP PARAMETERS::INHIBIT ALARMS Alarms 0 : Enabled 1 : Inhibited Enabled ck
19 RW Field Fail SETUP PARAMETERS::INHIBIT ALARMS Alarms 0 : Enabled 1 : Inhibited Enabled aj
540 RW REM Trip Inhibit SETUP PARAMETERS::INHIBIT ALARMS Alarms 0 : Enabled 1 : Inhibited Enabled p0
81 RW SPEED FBK ALARM SETUP PARAMETERS::INHIBIT ALARMS Alarms 0 : Enabled 1 : Inhibited Enabled c9
28 RW Stall Trip SETUP PARAMETERS::INHIBIT ALARMS Alarms 0 : Enabled 1 : Inhibited Inhibited as
305 RW Trip Reset SETUP PARAMETERS::INHIBIT ALARMS Alarms 0 : False 1 : True TRUE ih
204 RW Aiming Point SETUP PARAMETERS::INVERSE TIME Inverse Time 0.00 to 103.00 % 103.00% fo 2, 4
199 RW Delay SETUP PARAMETERS::INVERSE TIME Inverse Time 0.1 to 600.0 Secs 10.0 Secs fj 2, 4
200 RW Rate SETUP PARAMETERS::INVERSE TIME Inverse Time 0.1 to 600.0 Secs 60.0 Secs fk 2, 4
225 RW Crawl Speed SETUP PARAMETERS::JOG/SLACK Jog/Slack -100.00 to 100.00 % 10.00% g9
218 RW Jog Speed 1 SETUP PARAMETERS::JOG/SLACK Jog/Slack -100.00 to 100.00 % 20.00 % g2
219 RW Jog Speed 2 SETUP PARAMETERS::JOG/SLACK Jog/Slack -100.00 to 100.00 % -5.00 % g3
228 RW Mode SETUP PARAMETERS::JOG/SLACK Jog/Slack 0 : False 1 : True FALSE gc
355 RW Ramp Rate SETUP PARAMETERS::JOG/SLACK Jog/Slack 0.1 to 600.0 Secs 1.0 Secs jv
253 RW Take Up 1 SETUP PARAMETERS::JOG/SLACK Jog/Slack -100.00 to 100.00 % 5.00% h1
254 RW Take Up 2 SETUP PARAMETERS::JOG/SLACK Jog/Slack -100.00 to 100.00 % -5.00% h2
514 RW Ramp Accel Time SETUP PARAMETERS::OP STATION::LOCAL
RAMP
Op Station 0.1 to 600.0 Secs 10.0 Secs oa
515 RW Ramp Decel Time SETUP PARAMETERS::OP STATION::LOCAL
RAMP
Op Station 0.1 to 600.0 Secs 10.0 Secs ob
513 RW Jog Setpoint SETUP PARAMETERS::OP STATION::SET UP Op Station 0.00 to 100.00 % 5.00% o9 1
511 RW Local Key Enable SETUP PARAMETERS::OP STATION::SET UP Op Station 0 : False 1 : True TRUE o7
512 RW Setpoint SETUP PARAMETERS::OP STATION::SET UP Op Station 0.00 to 100.00 % 0.00% o8 1
516 RW Forward SETUP PARAMETERS::OP STATION::START
UP VALUES
Op Station 0 : False 1 : True TRUE oc
520 RW Jog Setpoint SETUP PARAMETERS::OP STATION::START
UP VALUES
Op Station 0.00 to 100.00 % 5.00% og
517 RW Local SETUP PARAMETERS::OP STATION::START
UP VALUES
Op Station 0 : False 1 : True TRUE od
518 RW Program SETUP PARAMETERS::OP STATION::START
UP VALUES
Op Station 0 : False 1 : True FALSE oe
519 RW Setpoint SETUP PARAMETERS::OP STATION::START
UP VALUES
Op Station 0.00 to 100.00 % 0.00% of
257 RW Decrease Rate SETUP PARAMETERS::RAISE/LOWER Raise/Lower 0.1 to 600.0 Secs 10.0 Secs h5
307 RW External Reset SETUP PARAMETERS::RAISE/LOWER Raise/Lower 0 : False 1 : True FALSE ij
256 RW Increase Rate SETUP PARAMETERS::RAISE/LOWER Raise/Lower 0.1 to 600.0 Secs 10.0 Secs h4
262 RW Lower Input SETUP PARAMETERS::RAISE/LOWER Raise/Lower 0 : False 1 : True FALSE ha
259 RW Max Value SETUP PARAMETERS::RAISE/LOWER Raise/Lower -300.00 to 300.00 % 100.00% h7
258 RW Min Value SETUP PARAMETERS::RAISE/LOWER Raise/Lower -300.00 to 300.00 % -100.00% h6
261 RW Raise Input SETUP PARAMETERS::RAISE/LOWER Raise/Lower 0 : False 1 : True FALSE h9
255 RW Reset Value SETUP PARAMETERS::RAISE/LOWER Raise/Lower -300.00 to 300.00 % 0.00% h3
266 RW % S-RAMP SETUP PARAMETERS::RAMPS Ramps 0.00 to 100.00 % 2.50% he
287 RW Auto Reset SETUP PARAMETERS::RAMPS Ramps 0 : Disabled 1 : Enabled Enabled hz
4 RW Constant Accel SETUP PARAMETERS::RAMPS Ramps 0 : Disabled 1 : Enabled Enabled a4
288 RW External Reset SETUP PARAMETERS::RAMPS Ramps 0 : Disabled 1 : Enabled Disabled i0
620 RW Invert SETUP PARAMETERS::RAMPS Ramps 0 : False 1 : True False
126 RW MIN SPEED SETUP PARAMETERS::RAMPS Ramps 0.00 to 100.00 % 0.00% di
2 RW Ramp Accel Time SETUP PARAMETERS::RAMPS Ramps 0.1 to 600.0 Secs 10.0 Secs a2
3 RW Ramp Decel Time SETUP PARAMETERS::RAMPS Ramps 0.1 to 600.0 Secs 10.0 Secs a3
118 RW Ramp Hold SETUP PARAMETERS::RAMPS Ramps 0 : Off 1 : On Off da
5 RW Ramp Input SETUP PARAMETERS::RAMPS Ramps -105.00 to 105.00 % 0.00% a5
286 RW RAMPING THRESH. SETUP PARAMETERS::RAMPS Ramps 0.00 to 100.00 % 0.50% hy
422 RW Reset Value SETUP PARAMETERS::RAMPS Ramps -300.00 to 300.00 % 0.00% lq
131 RW Deadband Width SETUP PARAMETERS::SETPOINT SUM 1 Setpoint Sum 1 0.00 to 100.00 % (h) 0.0% dn
420 RW Divider 0 SETUP PARAMETERS::SETPOINT SUM 1 Setpoint Sum 1 -3.0000 to 3.0000 1.0000 lo
419 RW Divider 1 SETUP PARAMETERS::SETPOINT SUM 1 Setpoint Sum 1 -3.0000 to 3.0000 1.0000 ln