Baldor mn792 Universal Remote User Manual


 
5-8 Switch Setting & Start-Up MN792
Power up in Remote Mode with Feedback Continued
8. Verify that C9 is +24VDC (reference to B1), and that B3 is 10VDC (reference to B1).
9. Select the Speed Feedback type.
Action Description Display Comments
Press B
Scroll to Configure Drive menu.
MENU LEVEL
CONFIGURE DRIVE
Press M key Access Configure Drive menu.
CONFIGURE DRIVE
CONFIGURE ENABLE
Press M key Access the Configure Enable
parameter.
CONFIGURE ENABLE
DISABLED
Press Y
Enable Configure Enable.
CONFIGURE ENABLE
ENABLED
All LEDs are now flashing.
Press E when done.
Press E key Returns to previous menu level.
CONFIGURE DRIVE
CONFIGURE ENABLE
Press B
Scroll to Speed FBK Select
CONFIGURE DRIVE
SPEED FBK SELECT
Press M key Access FBK select
SPEED FBK SELECT
ARM VOLTS FBK
Press Y to change to Analog Tach,
Encoder or Encoder/Analog.
Press E when done.
10. If using a potentiometer for a setpoint, verify its operation as follows:
a. Use the keypad to display the value of the Diagnostics::ANIN 3 (A4).
b. Vary the setpoint potentiometer and observe the input voltage change on the keypad display.
c. Additional Setpoint Inputs may also appear at ANIN 1 (A2) and ANIN 2 (A3).
Verify these if they are installed.
d. The sum of all the setpoints is given by the value of the Speed Setpoint parameter. This can be
verified from the keypad display.
11. Verify External Current Limit settings, if used.
If using a single external clamp, A6 low (0V). Verify ANIN 5 (A6) is +10V or is adjustable up to +10V.
If using dual external clamps, A6 high (+24V). Verify ANIN 5 (A6) is at +10V or is adjustable up to
+10V and that ANIN 4 (A5) is at +10V.
12. Verify speed feedback device, if possible.
a. Analog Tachometer The voltage at G3 (DC Tach Input) should go positive when shaft is
rotated in the forward direction.
b. Encoder The ENCODER parameter should give a positive reading when shaft is rotated in the
forward direction. Also check the Speed Feedback parameter is reading a positive value.
13. Set Main Current Limit to 0.00% to limit the motor current.
Action Description Display Comments
Press B
Scroll to Setup Parameters menu
MENU LEVEL
DIAGNOSTICS
Press M key Access the Setup Parameters menus
MENU LEVEL
SETUP PARAMETERS
Press B
Scroll to Current Loop
SETUP PARAMETERS
CURRENT LOOP
Press M key Access Current Loop parameters
CURRENT LOOP
MAIN CUR LIMIT
Press M key Access Main Current Limit parameter
MAIN CURR LIMIT
90.01%
Press B
MAIN CURR LIMIT
0.00%
Change the Main Current Limit to
0.00%. Press E when done