Baldor mn792 Universal Remote User Manual


 
Programming 6-7MN792
Analog Outputs Continued
Example 1 Read the field current feedback using Analog Output 1.
The tag number for the field current feedback parameter is 300.
1. Set CONFIGURE I/O::CONFIGURE ENABLE to Enable.
2. Set ANALOG OUTPUTS::ANOUT 1 (A7):: SOURCE TAG to 300.
3. Set ANALOG OUTPUTS::ANOUT 1 (A7):: % TO GET 10 VDC to 100% (factory setting).
4. Set SETUP PARAMETERS::CALIBRATION::ARMATURE I (A9) to Bipolar (factory setting).
5. Reset CONFIGURE I/O::CONFIGURE ENABLE to Disable.
[182] Field I CAL 1.0000
Analog
Output 3
[25] Armature I (A9)
To Field
Control
Bipolar
UNI
Power Board
Calibration Board
I
Arm
I
Field
Setup Parameters::Calibration::
Tag Parameter
[245] % to get to 10V
+100.00%
[464] Offset 0.00%
Setting
[362] Modulus
False
Analog
Output 1
ANOUT 1 (A7)
[251] Source Tag 300
ABS
A7
Tag Parameter
Setting
A9
[300]
[181]
Example 2 Connect the serial link to Analog Output 1.
Allows analog output 1 to read values written by an external device to PNO 58 (ASCII 3A) which is AUX I/O
Analog Out 1. The tag number for the AUX I/O::ANOUT 1 parameter is 128.
1. Set CONFIGURE I/O::CONFIGURE ENABLE to Enable.
2. Set ANALOG OUTPUTS::ANOUT 1 (A7):: SOURCE TAG to 128.
3. Set ANALOG OUTPUTS::ANOUT 1 (A7):: % TO GET 10V to 100% (factory setting).
4. Reset CONFIGURE I/O::CONFIGURE ENABLE to Disable.
[94] AUX Digout 1
OFF
Setup Parameters::AUX I/O::
Tag Parameter
[245] % to get to 10V +100.00%
[464] Offset 0.00%
Setting
[362] Modulus
False
Analog
Output 1
ANOUT 1 (A7)
[251] Source Tag 128
ABS
A7
[95] AUX Digout 2
OFF
[96] AUX Digout 3
OFF
[128] AUX Anout 1
0.00%
[129] AUX Anout 2
0.00%
Tag Parameter Setting
Example 3 Connect the current demand to Analog Output 2.
The tag number for the current demand parameter is 66.
1. Set CONFIGURE I/O::CONFIGURE ENABLE to Enable.
2. Set ANALOG OUTPUTS::ANOUT 2 (A8):: SOURCE TAG to 66.
3. Set ANALOG OUTPUTS::ANOUT 2 (A8):: % TO GET 10V to 200%.
4. Reset CONFIGURE I/O::CONFIGURE ENABLE to Disable.
Setting % TO GET 10V at 200% results in 5 volts output when current feedback is at 100%.
[66] Current Demand N/A
Setup Parameters::Current Loop::
Tag Parameter
[248] % to get to 10V
+200.00%
[465] Offset 0.00%
Setting
[363] Modulus
False
Analog
Output 2
ANOUT 2 (A8)
[252] Source Tag 66
ABS
A8
Tag Parameter Setting