Baldor mn792 Universal Remote User Manual


 
B-4 Parameter Table MN792
Table B-1 Parameters Listed by Tag Number Continued
Tag R/W Name Keypad Menu WB Block Range Factory Setting MN Notes
181 RO Unfil. Field FBK DIAGNOSTICS Calibration xxx.xx % 0.00% f1 Output
182 RW Field I CAL. SETUP PARAMETERS::CALIBRATION Calibration 0.9800 to 1.1000 1.0000 f2
183 RO Field Demand DIAGNOSTICS Field Control xxx.xx % 0.00% f3 Output
184 RO FLD.FIRING ANGLE DIAGNOSTICS Field Control xxx.xx DEG 0.00 Deg f4 Output
185 RW FLD.QUENCH
DELAY
SETUP PARAMETERS::FIELD CONTROL Field Control 0.0 to 600.0 Secs 0.0 Secs f5
186 RW FLD. QUENCH
MODE
SETUP PARAMETERS::FIELD CONTROL Field Control 0 : Quench 1 : Standby Quench f6
187 RO Raw Input SERIAL LINKS::SYSTEM PORT (P3)::P3 SETĆ
UP::5703 SUPPORT
5703 xxx.xx % 0.00% f7 Output
188 RW Over Speed Level SETUP PARAMETERS::CALIBRATION Calibration 0.00 to 200.00 % 125.00% f8 4
189 RO Scaled Input SERIAL LINKS::SYSTEM PORT (P3)::P3 SETĆ
UP::5703 SUPPORT
5703 xxx.xx % 0.00% f9 Output, 2
191 RW BEMF FBK LEAD SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS::FLD.WEAK VARS
Field Control 10 to 5000 100 fb
192 RW BEMF FBK LAG SETUP PARAMETERS::FIELD CONĆ
TROL::FLD.CURRENT VARS::FLD.WEAK VARS
Field Control 10 to 5000 100 fc
195 RW Threshold (>) SYSTEM::CONFIGURE I/O::DIGITAL OUTĆ
PUTS::DIGOUT 1 (B5)
Digout 1 (B5) -300.00 to 300.00 % 0.00% ff 2
196 RW Threshold (>) SYSTEM::CONFIGURE I/O::DIGITAL OUTĆ
PUTS::DIGOUT 2 (B6)
Digout 2 (B6) -300.00 to 300.00 % 0.00% fg 2
197 RW Threshold (>) SYSTEM::CONFIGURE I/O::DIGITAL OUTĆ
PUTS::DIGOUT 3 (B7)
Digout 3 (B7) -300.00 to 300.00 % 0.00% fh 2
198 RW P3 Baud Rate SERIAL LINKS::SYSTEM PORT (P3)::P3 SETĆ
UP
0:300 1:600 2:1200
3:2400 4:4800 5:9600
6:19200
9600 fi 2
199 RW Delay SETUP PARAMETERS::INVERSE TIME Inverse Time 0.1 to 600.0 Secs 10.0 Secs fj 2, 4
200 RW Rate SETUP PARAMETERS::INVERSE TIME Inverse Time 0.1 to 600.0 Secs 60.0 Secs fk 2, 4
201 RW Regen Mode SETUP PARAMETERS::CURRENT LOOP Current Loop 0 : 2Q (Non-regen)
1 : 4Q (Regen)
2Q(Non-regen) fl 2
202 RW INT. DEFEAT SETUP PARAMETERS::SPEED LOOP Speed Loop 0 : Off 1 : On Off fm
203 RO Inverse Time O/P DIAGNOSTICS Inverse Time xxx.xx % 200.0% fn Output, 2, 4
204 RW Aiming Point SETUP PARAMETERS::INVERSE TIME Inverse Time 0.00 to 103.00 % 103.00% fo 2, 4
206 RO Encoder DIAGNOSTICS Diagnostics xxxxx RPM 0 RPM fq Output
207 RO Speed Feedback DIAGNOSTICS Diagnostics xxx.xx % 0.01% fr Output
208 RW Ratio 0 SETUP PARAMETERS::SETPOINT SUM 1 Setpoint Sum 1 -3.0000 to 3.0000 1.0000 fs
209 RW FLD.CTRL MODE CONFIGURE DRIVE Field Control 0 : Voltage Control
1 : Current Control
Voltage Control ft 2
210 RW FLD.VOLTS RATIO CONFIGURE DRIVE Field Control 0.00 to 100.00 % (h) 67.0% fu
212 RO Operating Mode DIAGNOSTICS Jog/Slack 0 : Stop
1 : Stop
2 : Jog Sp. 1
3 : Jog Sp. 2
4 : Run
5 : Take Up Sp. 1
6 : Take Up Sp. 2
7 : Crawl
Stop fw Output
216 RW PROG STOP LIMIT SETUP PARAMETERS::STOP RATES Stop Rates 0.0 to 600.0 Secs 60.0 Secs g0
217 RW Stop Limit SETUP PARAMETERS::STOP RATES Stop Rates 0.0 to 600.0 Secs 60.0 Secs g1
218 RW Jog Speed 1 SETUP PARAMETERS::JOG/SLACK Jog/Slack -100.00 to 100.00 % 20.00 % g2
219 RW Jog Speed 2 SETUP PARAMETERS::JOG/SLACK Jog/Slack -100.00 to 100.00 % -5.00 % g3
224 RW Stall Trip Delay SETUP PARAMETERS::CALIBRATION Calibration 0.1 to 600.0 Secs 10.0 Secs g8
225 RW Crawl Speed SETUP PARAMETERS::JOG/SLACK Jog/Slack -100.00 to 100.00 % 10.00% g9
227 RW AUX JOG SETUP PARAMETERS::AUX I/O Aux I/O 0 : Off 1 : On On gb
228 RW Mode SETUP PARAMETERS::JOG/SLACK Jog/Slack 0 : False 1 : True FALSE gc
230 RW Calibration SYSTEM::CONFIGURE I/O::ANALOG INĆ
PUTS::ANIN 1 (A2)
Analog Input 1 -3.0000 to 3.0000 1.0000 ge
231 RW Max Value SYSTEM::CONFIGURE I/O::ANALOG INĆ
PUTS::ANIN 1 (A2)
Analog Input 1 -300.00 to 300.00 % 100.00% gf
232 RW Min Value SYSTEM::CONFIGURE I/O::ANALOG INĆ
PUTS::ANIN 1 (A2)
Analog Input 1 -300.00 to 300.00 % -100.00% gg