Baldor mn792 Universal Remote User Manual


 
5-14 Switch Setting & Start-Up MN792
Starting and Stopping Methods Continued
Normal Stop
Action Remove 24V from Terminal C3 to stop. The motor speed is brought to zero in a time defined by the
Stop Time parameter.
t
0%
t
t
0%
t
0%
0%
Actual stopping rate depends
on load inertia, motor hp, and
overload capability of the drive.
Drive is disabled below stop
zero speed if set > 0.25%
Drive remains enabled for contactor
delay if stop zero speed < 0.25%
0%
0%
0%
t
t
t
Contactor will not drop out if
Speed Feedback > Stop Zero Speed
when stop limit timed out
t
Normal Stop
Speed Setpoint (100%)
Start/Run (C3)
Speed Demand
Stop Time (10 Seconds)
Control Signals
Speed Demand
Actual Speed
Enable
Control Signals
Speed Demand
Actual Speed
Speed Feedback
=Speed Setpoint
Stop Zero
Speed (2%)
Drive Enable = Enabled
(Display Diagnostic)
Drive Enable = Disabled
Time Out in Normal Stop
Speed Setpoint
Start/Run (C3)
Speed Demand
Speed Setpoint
100% = Speed Setpoint
=Speed Setpoint
Stop Limit (60.0 Seconds)
Stop Zero Speed (2%)