Chapter 2-Additional Conferencing Information
2-72
MGC to RMX 2000 Cascading
MGC is always on level 1 and must be set as the Master MCU. If the
cascading topology includes additional MGCs as well as RMXs it is
recommended to define Video Switching conferences for all the cascading
conferences in the topology.
Depending on the dialing direction, the following procedures must be
performed:
Table 2-16 Set up Procedures according to the Dialing Direction
Dialing
Direction
MGC Level 1 RMX 2000 Level 2
MGC to
RMX 2000
Set the appropriate flags
(done once only).
Set the appropriate flags (done
once only).
Define the cascade-enabled
Entry Queue, setting it as Slave.
Define the conference
setting and its line rate to be
the same as the one set on
the RMX 2000.
Define the conference setting
and its line rate to be the same
as the one set on the MGC.
Define the dial-out
participant (Cascaded Link)
to the conference running
on the RMX 2000.
Level 1 (Master)
Level 2 (Slave to Level 1)