Polycom 2000 Home Theater Server User Manual


 
Polycom RMX 2000 Administrator’s Guide
C-23
Table C-8 Event Fields for Event 2 - CONFERENCE END
Field Description
Conference End
Cause
Indicates the reason for the termination of the
conference, as follows:
1 - The conference is an ongoing conference or the
conference was terminated by an MCU reset.
2 - The conference was terminated by a user.
3 - The conference ended at the scheduled end time.
4 - The conference ended automatically because no
participants joined the conference for a predefined time
period, or all the participants disconnected from the
conference and the conference was empty for a
predefined time period.
5 - The conference never started.
6 - The conference could not start due to a problem.
8 - An unknown error occurred.
9 - The conference was terminated by a participant using
DTMF codes.
Table C-9 Event fields for Event 3 - ISDN/PSTN CHANNEL
CONNECTED
Field Description
Participant Name The name of the participant.
Participant ID The identification number assigned to the participant by
the MCU.
Channel ID The channel identifier.
Number of
Channels
The number of channels being connected for this
participant.
Connect Initiator Indicates who initiated the connection, as follows:
0 - RMX
1 - Participant
Any other number - Unknown