Polycom 2000 Home Theater Server User Manual


 
Polycom RMX 2000 Administrator’s Guide
B-11
Single clock source No Backup clock could be established as only one span
is connected to the system or, there is a synchronization
failure with another span. This alarm can be cancelled by
adding the appropriate flag is the system configuration.
SIP registrations limit reached SIP registrations limit reached.
SIP TLS: Failed to load or verify certificate
files
This alarm indicates that the certificate files required for
SIP TLS could not be loaded to the RMX. Possible
causes are:
Incorrect certificate file name. Only files with the
following names can be loaded to the system:
rootCA.pem, pkey.pem, cert.pem and
certPassword.txt
Wrong certificate file type. Only files of the following
types can be loaded to the system: rootCA.pem,
pkey.pem and cert.pem and certPassword.txt
The contents of the certificate file does not match the
system parameters
SIP TLS: Registration transport error This alarm indicates that the communication with the SIP
server cannot be established. Possible causes are:
Incorrect IP address of the SIP server
The SIP server listening port is other than the one
defined in the system
The OCS services are stopped
SIP TLS: Registration handshake failure This alarm indicates a mismatch between the security
protocols of the OCS and the RMX, preventing the
Registration of the RMX to the OCS.
Table B-1 Alarms (Continued)
Alarm Code Alarm Description