Polycom RMX 2000 Administrator’s Guide
C-33
Table C-15 Event Fields for Events 2010, 2101, 2105 - DEFINED PARTICIPANT
CONTINUE 1, USER ADD PARTICIPANT CONTINUE 1, USER
UPDATE PARTICIPANT CONTINUE 1
Field Description
Network Type The type of network between the participant and the
MCU, as follows:
0 - ISDN/PSTN
2 - H.323
5 - SIP
H.243 Password Not supported.
This field remains empty.
Chair Not supported.
Always contains the value 0.
Video Protocol The video protocol used by the participant, as follows:
1 - H.261
2 - H.263
4 - H.264
255 - Auto
Broadcasting
Volume
The broadcasting volume assigned to the participant.
The value is between 1 (lowest) and 10 (loudest).
Each unit movement increases or decreases the volume
by 3 dB.
Undefined
Participant
Indicates whether are not the participant is an undefined
participant, as follows:
0 - The participant is not an undefined participant.
2 - The participant is an undefined participant.
Node Type The node type, as follows:
0 - MCU
1 - Terminal