Polycom 2000 Home Theater Server User Manual


 
Polycom RMX 2000 Administrator’s Guide
16-7
System Alerts
System Alerts are activated when the system encounters errors such as a
general or card error. The system errors are recorded by the RMX and can
be generated into a report that can be saved in *.txt format.
To view the System Alerts list:
1 Click the red blinking System Alerts indication bar.
The System Alerts pane opens. This screen indicates what events have
not been resolved.
The following columns appear in the System Alerts pane:
Table 16-1 Active Alarms Pane Columns
Field Description
ID An identifying number assigned to the system alert.
Time Lists the date and time that the error occurred. This
column also includes the icon indicating the error
level (as listed in the level column).
Category Lists the type of error. The following categories may
be listed:
File – indicates a problem in one of the files
stored on the MCU’s hard disk.
Card – indicates problems with a card.
Exception – indicates software errors.
General – indicates a general error.
Assert – indicates internal software errors that
are reported by the software program.
Startup – indicates errors that occurred during
system startup.
Unit – indicates problems with a unit.
MPL - indicates an error related to a Shelf
Management component (MPL component)
other than an MPM, RTM or switch board.