Mitsubishi Electronics FX3G Universal Remote User Manual


 
11 Use of High-speed Counters
11.5 Handling of High-speed Counters
165
FX3G Series Programmable Controllers
User's Manual - Hardware Edition
11
High-Speed
Counters
12
Output Wiring
13
Wiring for
Various Uses
14
Test Run,
Maintenance,
Troubleshooting
15
Input/Output
Powered
Extension Units
16
Input/Output
Extension
Blocks
17
Extension
Power Supply
Unit
18
Other Extension
Units and
Options
19
Display Module
20
Terminal Block
11.5.3 2-phase 2-count input
These counters are 32-bit up-count/down-count binary counters.
The operations of the output contact according to the current value are the same as those of the above-
mentioned 1-phase 1-count input high-speed counters.
Examples of program
1) For C251
While X012 is on, C251 counts the operation of the input
terminals X000 (A-phase) and X001 (B-phase) through
interruption.
While X011 is turned on, the counter is reset when RST
instruction is executed.
When the current value exceeds the setting, Y002 turns on, and
when the current value becomes lower than the setting, Y002
turns off.
Y003 turns on (down-count) or off (up-count) according to the
counting direction.
2) For C254
C254 starts counting immediately when the input terminal
X006 is turned on while X012 is on.
The count input terminals are X000 (A-phase) and X001
(B-phase).
C254 is reset by X011 on the sequence, and it is reset
immediately when X002 is turned on.
When the current value exceeds the setting (D1,D0), Y004
operates, and when the current value becomes lower than
the setting, Y004 turns off.
Y005 turns on (down-count) or off (up-count) according to
the counting direction.
A 2-phase encoder generates A-phase output and B-phase output between which there is a 90 phase
difference. The high-speed counter automatically counts up or down according to the output as shown
below.
The down-count/up-count operations of C251 to C255 can be monitored through the ON/OFF operations
of M8251 to M8255.
ON: Down-counting
OFF: Up-counting
X011
X012
C251
K1234
RST C251
C251
Y002
M8251
Y003
Main unit
A-phase input
B-phase input
X001X000
X011
X012
C254
D0(D1)
C254
Y004
M8254
Y005
RST C254
X000
Main unit
A-phase input
X001
B-phase input
X002 X006
External reset
input
External start input
The setting is (D1,D0).
Phase A
Phase B
+1
+1
Up-counting
-1
-1
Down-counting