20 Terminal Block
20.8 FX-16EYT-TB, FX-16EYT-H-TB
369
FX3G Series Programmable Controllers
User's Manual - Hardware Edition
11
High-Speed
Counters
12
Output Wiring
13
Wiring for
Various Uses
14
Test Run,
Maintenance,
Troubleshooting
15
Input/Output
Powered
Extension Units
16
Input/Output
Extension
Blocks
17
Extension
Power Supply
Unit
18
Other Extension
Units and
Options
19
Display Module
20
Terminal Block
20.8 FX-16EYT-TB, FX-16EYT-H-TB
The FX-16EYT(-H)-TB is used by connecting it to the FX2N series output extension block (transistor).
The applications shown below are not supported.
20.8.1 Specifications
*1. This response time does not include the response delay at the PLC.
Output Connector
Connectable models FX2N-16EYT-C (sink output)
Unsupported Applications
Pulse outputs
Pulse Y output (PLSY) instruction, acceleration/deceleration setup (PLSR) instruction, pulse width modulation
(PWM) instruction, DOG search zero return (DSZR) instruction, batch data positioning mode (TBL) instruction,
absolute current value read (ABS) instruction, zero return (ZRN) instruction, variable speed pulse output (PLSV)
instruction, drive to increment (DRVI) instruction, drive to absolute (DRVA) instruction
Time division inputs Input matrix (MTR) instruction, digital switch (DSW) instruction
Time division output Seven segment with latch (SEGL) instruction
Item
Transistor output
FX-16EYT-TB FX-16EYT-H-TB
Input/output
circuitry
Load voltage 5 to 30V DC
Max.
load
Resistance
load
0.5A/point
The total load current of resistance loads per common
terminal should be the following value.
4 output points/common terminal: 0.8A or less
1A/point
The total load current of resistance loads per common
terminal should be the following value.
4 output points/common terminal: 3A or less
Inductive
load
12W/24V DC
The total of inductive loads per common terminal should
be the following value.
4 output point/common terminal: 19.2W or less/24V
DC
24W/24V DC
The total of inductive loads per common terminal should
be the following value.
4 output point/common terminal: 72W or less/24V
DC
Open-circuit
leakage current
0.1mA / 30V DC
Res-
ponse
time
OFF ON
*1
0.2ms or less/24V DC 0.3ms or less/24V DC
OFF ON
*1
1.5ms or less/24V DC 4ms or less/24V DC
Output element's
ON voltage
1.5V
Circuit isolation Photo-coupler isolation
Operation
indicators
Activation of the photo-coupler will light the LED indicator lamp on panel.
Power
consumption
2.7W (112mA 24V DC)
Photo-
coupler
3.3k
LED
24V DC
7mA
5 to 30V
DC
0 to 7
COMn
Fuse
CN1
Connector
side
External
wiring
24+
Photo-
coupler
LED
0 to 7
COMn
Fuse
CN1
Connector
side
3.3k
24V DC
7mA
External
wiring
5 to 30V
DC
24+