13 Examples of Wiring for Various Uses
194
FX3G Series Programmable Controllers
User's Manual - Hardware Edition
13.3 Input Matrix [MTR Instructions (FNC 52)]
3. Input/output powered extension unit
Example of program
Example of wiring
1) In the case of sink wiring
When inputs are used for sink only and outputs are the transistor sink type in the used input/output
powered extension unit
2) In the case of source wiring
When inputs are used for both sink and source and outputs are the transistor source type in the used
extension unit
M8000
X060 Y050 M30 K3MTR
Transistor output (sink)
FX2N-32ET
FX2N-48ET
Input/output powered extension unit
0.1A 50V
diode is
necessary.
COM X060
COM1
X061 X062 X063 X064 X065 X066 X067
Y050 Y051 Y052 Y053 Y054 Y055 Y056 Y057
M30
M31
M32
M33
M34
M35
M36
M37
M40
M41
M42
M43
M44
M45
M46
M47
M50
M51
M52
M53
M54
M55
M56
M57
X061 X062 X063 X064 X065 X066 X067
X061 X062 X063 X064 X065 X066 X067
24V X060
+V0
X061 X062 X063 X064 X065 X066 X067
Y050 Y051 Y052 Y053 Y054 Y055 Y056 Y057
Transistor output (source)
M30
M31
M32
M33
M34
M35
M36
M37
M40
M41
M42
M43
M44
M45
M46
M47
M50
M51
M52
M53
M54
M55
M56
M57
0.1A 50V
diode is
necessary.
0VS/S
Input/output powered extension unit
X061 X062 X063 X064 X065 X066 X067
X061 X062 X063 X064 X065 X066 X067
FX
2N
-32ET-ESS/UL
FX
2N
-48ET-ESS/UL