Mitsubishi Electronics FX3G Universal Remote User Manual


 
2 Features and Part Names
2.1 Major Features
30
FX3G Series Programmable Controllers
User's Manual - Hardware Edition
[Pulse output function]
When output terminals in the transistor output
type main unit are used, pulses of up to 100kHz
can be output simultaneously to 3 axes
*1
(Y000,
Y001 and Y002).
*1. 2 axes (Y000 and Y001) in 14-point and
24-point type main units
Using a number of instructions programming is
simplified.
Refer to Positioning Control Edition.
[Various positioning instructions]
Refer to Positioning Control Edition.
3. Display functions (display module)
(Supported in Ver. 1.10 or later)
FX3G-5DM Display Module (option) can be
incorporated in the PLC.
[Monitor/test function]
Devices can be monitored and tested by
operating the buttons on the display module.
The button operations can be inhibited by the
user program.
[Other functions]
On the display module, you can set the time,
adjust the contrast and display the PLC version
and error codes.
Refer to 19. Display Module (FX3G-5DM) in
this manual.
4. Communication and network functions
The expansion board, special adapter and
special function block for each communication
function can be connected.
[Kinds of communication functions]
Programming communication
(RS-232C/RS-422/USB)
N:N Network
Parallel link
Computer link
Inverter communication
(Supported in Ver. 1.10 or later)
Non-protocol communication
(Built-in RS-422/RS-232C/RS-485)
Refer to Data Communication Edition.
MODBUS communication
(Supported in Ver. 1.30 or later)
Refer to MODBUS Serial Communication
Edition.
Ethernet (Supported in Ver. 2.00 or later)
Refer to FX
3U-ENET-ADP User's Manual.
CC-Link
- Master station (Compatible with CC-Link
Ver. 2.00 and Ver. 1.10):
FX
3U-16CCL-M
- Master station (Compatible with CC-Link
Ver. 1.10):
FX
2N-16CCL-M
- Intelligent device station
FX3U-64CCL
- Remote device station
FX
2N-32CCL
Refer to the manual for each product.
CC-Link/LT
- Master station : FX
2N-64CL-M
- Remote I/O station, Remote device station
Refer to the manual for each product.
5. Analog functions
The expansion board, special adapter and
special function block for each analog function
are connected.
Refer to Analog Control Edition.
[Kinds of analog functions]
Voltage/current input
Voltage/current output
Temperature sensor input (thermocouple and
platinum resistance thermometer sensor)
Temperature control
Instruction Description
DSZR
Mechanical zero return instruction with DOG
search function
ABS
Instruction to read the current value from our
servo amplifier with absolute position (ABS)
detecting function
DRVI
Positioning (relative positioning) to specify the
movement from the current position
DRVA
Positioning (absolute positioning) to specify
the target position based on the current
value 0
PLSV
Instruction to change the pulse train output
frequency
TBL
Instruction for positioning based on batch
setting of positioning operation, moving
distance and speed