(Ref: 06116A) Addendum to the M200EM/EH Operators Manual (P/N 04521)
Addendum-2
2.2. THREE PORT REACTION CELL
By incorporating the bypass flow orifice into the reaction cell, the bypass manifold assembly,
which previously resided between the vacuum manifold and Molycon container, is no longer
required.
FIGURE 2.0 – THREE PORT REACTION CELL ASSY P/N 06028
Bypass Flow Orifice:
7 Mil for M200EM
3 Mil for M200EH
Ozone Flow Orifice:
7 Mil for M200EM Or EH
Sample Flow:
No Orifice
04521C (DCN5731)