Operating Instructions Teledyne API - Model 200EH/EM Operation Manual
76
6.7.2.7. RS-232 Report Function
The M200EH/EM iDAS can automatically report data to the communications ports, where they can be captured
with a terminal emulation program or simply viewed by the user.
To enable automatic COM port reporting, follow the instruction shown in section 6.7.2.2 then press:
Edit Data Channel Menu
SETUP X.X 0) CONC: ATIMER, 8, 800
PREV NEXT INS DEL
EDIT
PRNT
EXIT
Exits to the main
Data Acquisition
menu
SETUP X.X NAME:CONC
<SET
SET>
EDIT
PRINT EXIT
SETUP X.X RS-232 REPORT: OFF
<SET SET> EDIT PRINT EXIT
ENTR
accepts the new
setting and returns to the
previous menu.
EXIT
ignores the new setting
and returns to the previous
menu.
SETUP X.X RS-232 REPORT: OFF
OFF ENTR EXIT
Toggle key to turn
reporting ON or OFF
Press
SET>
key until…
From the
DATA ACQUISITION
menu
(see Section 6.7.2.2)
6.7.2.8. Compact Report
When enabled, this option avoids unnecessary line breaks on all RS-232 reports. Instead of reporting each
parameter in one channel on a separate line, up to five parameters are reported in one line, instead. For
example, channel DIAG would report its record in two lines (10 parameters) instead of 10 lines. Individual lines
carry the same time stamp and are labeled in sequence.
6.7.2.9. Starting Date
This option allows to specify a starting date for any given channel in case the user wants to start data acquisition
only after a certain time and date. If the
Starting Date is in the past, the iDAS ignores this setting.
04521C (DCN5731)