Teledyne 200EH/EM TV Converter Box User Manual


 
APPENDIX A-3: Warnings and Test Functions, Revision F.0 Model 200EH/EM (Ref: 05147F)
A-16
APPENDIX A-3: Warnings and Test Functions, Revision F.0
Table A-2: M200EH/EM Warning Messages, Revision F.0
Name Message Text Description
WSYSRES
SYSTEM RESET
Instrument was power-cycled or the CPU was reset.
WDATAINIT
DATA INITIALIZED
Data storage was erased.
WCONFIGINIT
CONFIG INITIALIZED
Configuration storage was reset to factory configuration or erased.
WSAMPFLOW
SAMPLE FLOW WARN Sample flow outside of warning limits specified by SFLOW_SET
variable.
WOZONEFLOW
OZONE FLOW WARNING Ozone flow outside of warning limits specified by OFLOW_SET
variable.
WOZONEGEN
OZONE GEN OFF Ozone generator is off. This is the only warning message that
automatically clears itself. It clears itself when the ozone generator
is turned on.
WRCELLPRESS
RCELL PRESS WARN Reaction cell pressure outside of warning limits specified by
RCELL_PRESS_SET variable.
WBOXTEMP
BOX TEMP WARNING Chassis temperature outside of warning limits specified by
BOX_SET variable.
WRCELLTEMP
RCELL TEMP WARNING Reaction cell temperature outside of warning limits specified by
RCELL_SET variable.
WMANIFOLDTEMP
4
MANIFOLD TEMP WARN Bypass or dilution manifold temperature outside of warning limits
specified by MANIFOLD_SET variable.
WO2CELLTEMP
5
O2 CELL TEMP WARN O2 sensor cell temperature outside of warning limits specified by
O2_CELL_SET variable.
WIZSTEMP
IZS TEMP WARNING IZS temperature outside of warning limits specified by IZS_SET
variable.
WCONVTEMP
CONV TEMP WARNING Converter temperature outside of warning limits specified by
CONV_SET variable.
WPMTTEMP
PMT TEMP WARNING PMT temperature outside of warning limits specified by PMT_SET
variable.
WAUTOZERO
AZERO WRN XXX.X MV Auto-zero reading above limit specified by AZERO_LIMIT variable.
Value shown in message indicates auto-zero reading at time
warning was displayed.
WHVPS
HVPS WARNING High voltage power supply output outside of warning limits
specified by HVPS_SET variable.
WDYNZERO
CANNOT DYN ZERO Contact closure zero calibration failed while DYN_ZERO was set to
ON.
WDYNSPAN
CANNOT DYN SPAN Contact closure span calibration failed while DYN_SPAN was set
to ON.
WREARBOARD
REAR BOARD NOT DET
Rear board was not detected during power up.
WRELAYBOARD
RELAY BOARD WARN
Firmware is unable to communicate with the relay board.
WFRONTPANEL
FRONT PANEL WARN
Firmware is unable to communicate with the front panel.
WANALOGCAL
ANALOG CAL WARNING
The A/D or at least one D/A channel has not been calibrated.
1
O
2
option.
04521C (DCN5731)