Avaya S8100 Home Theater Server User Manual


 
1Install and cable a G600 cabinet
Install off-premises station wiring
S8100 Installation and Upgrades 123
November 2003
Figure 40: Connections for one to eight out-of-building analog telephones
Figure 41, Connections to 24 out-of-building telephones, on page 124 shows the connections for up to 24
off-premises analog telephones, with concentrations of analog line pairs used at both buildings to
minimize the off-premises wiring required. At the MDF, jumpers must be connected between 1
row/connecting block in the white field and up to 3 rows/connecting blocks in the purple field. At the
station location, a WP-90929, List 1 concentrator cable is used. There are 8 station appearances on each
of the 3 fingers of the concentrator cable. See Figure 41, Connections to 24 out-of-building telephones,
on page 124.
c
r
d
f
obt
RPY
0
12
398
1
2
3 3
4
5
5
5
6
6
7
8 9
10
11
Figure notes
1 Locally engineered cables
2 Out-of-building wiring
3 Multipair protector units (primary
protectors with heat coils or equivalent
with sneak-current protection)
4 356A adapter
5 B25A cable
6 Out-of-building analog telephones
7 Part of MDF or patch panel
8 Station side (white field)
9 System side (purple field)
10 Cross-connect jumpers
11 To Analog Line circuit pack (TN2183,
TN769, TN742, or TN746B)