Avaya S8100 Home Theater Server User Manual


 
6 Hardware additions
Add CO, FX, WATS, and PCOL
236 S8100 Installation and Upgrades
November 2003
7 If the echo still exists, set the EC Configuration: field to 2, 3, or 4, then test the voice
quality. These settings provide help for the following scenarios:
Setting 2 – Minimizes speech clipping, but it takes a fraction of a second longer for the
echo to fade.
Setting 3 – Eliminates speech clipping, but a strong echo may take 2 or 3 seconds to fade.
Setting 4 – Minimizes extremely strong echo, very hot signals, or excessive clipping or
breakup of speech from a distant party. It reduces speech clipping but may allow slight
residual echo or more background noise.
8 If the echo still exists after trying every previous setting, contact technical support.
Add CO, FX, WATS, and PCOL
Requirements
Each Central Office (CO), Foreign Exchange (FX), Personal Central Office Line (PCOL), or Wide Area
Telecommunications Service (WATS) trunk connects to 1 port of either an 8-port TN747B or to 1 of
several CO trunk circuit packs.
Installation
1 Determine the port assignment of the trunk from Trunk Group form.
2 Install a TN747B or a CO Trunk circuit pack in the assigned carrier slot (if an additional circuit
pack is required).
3 Administer the forms listed under CO, FX, WATS, or PCOL Trunk Group in Administrator’s
Guide for Avaya Communication Manager (555-233-506).
Add DID trunks
Requirements
Each Direct Inward Dial (DID) trunk connects to 1 port DID Trunk circuit pack or to 1 port of an
assortment of DID trunk circuit packs.
EXAMPLE: Port number 3 A 07 01
Cabinet Carrier Slot Circuit
(Port network) (or compact modular
cabinet)