Avaya S8100 Home Theater Server User Manual


 
3System initialization
Administer Communication Manager for INTUITY AUDIX initialization
S8100 Installation and Upgrades 189
November 2003
2 For example, to define 3000 – 3999 as an extension range:
a type 3 in the Dialed String column
b in the same row, type 4 in the Total Length column
c type ext in the Call Type column
3 For example, to specify that the range 700 – 799 is to be used for dial access codes:
a type 7 in the Dialed String column
b in the same row, type 3 in the Total Length column
c type dac in the Call Type column
4 Submit the form to save your changes.
Add AUDIX ports
Stations are added by entering a change machine command with the starting and ending numbers (for
example, 0000 – 9999 starting and ending range for a 4-digit extension length).
NOTE:
Check the Dialplan Analysis Table for the correct extension lengths.
To set up stations for INTUITY AUDIX ports:
1 At the SAT or Avaya Site Administration window, enter add sta <number>, where number is
the station you want to use for the first INTUITY AUDIX port.
The Station form displays:
2 Type 2500 in the Type field.
3 Type 01A1201 in the Port field. This is a virtual port used to communicate between
Communication Manager and INTUITY AUDIX.
4 Type a name in the Name field.
5 Enter the correct COR and COS.
add station 2001 Page 1 of 4
STATION
Extension: 2001 Lock Messages? n BCC: 0
Type: Security Code: TN: 1
Port: Coverage Path 1: COR: 2
Name: Coverage Path 2: COS: 5
Hunt-to Station:
STATION OPTIONS
Loss Group: 2 Personalized Ringing Pattern: 1
Data Module? n Message Lamp Ext: 2017
Speakerphone: 2-way Mute Button Enabled? y
Display Language: english
Media Complex Ext:
IP SoftPhone? n