1 Install and cable a G600 cabinet
Install emergency-transfer panel and associated telephones
132 S8100 Installation and Upgrades
November 2003
Figure 43: Connections for telephone used for emergency transfer
Figure 44, Connections for telephone used for emergency transfer and as normal extension, on page 133
shows the connections at the trunk/auxiliary field for a telephone used for emergency transfer and as a
normal extension.
TC TK LC ST
1M 1m 2M 2m 3M
ALARM MONITORS EM TRANS RELAY PWR ACC PWR
3m 3w
TC TK LC ST TC TK LC ST TC TK LC ST TC TK LC ST
C
O
M
1
N
O
1
N
C
2
N
C
1
C
O
M
2
N
O
2
C
O
M
3
N
C
3
G
R
D
-48
V
123
2822
25
50
1
EMXR
2822
r758580b MMR 042996
Figure notes
1 To network interface circuitry
2 To CO Trunk circuit pack
3 To blue or white station distribution field
4 To power-transfer unit
5 To control carrier’s AUX connector