Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
2 Wiring and Connection
MITSUBISHI CNC
2 - 36
The following cable can simplify the wiring.
Connection drawing
The signal cable connection is a one-on-one connection (One pin is connected to one pin).
The case GND planes (connector housings) of each connector are connected using with an F
installation plate.
Precautions for manufacturing
The parts are those recommended by Mitsubishi, and can be replaced with equivalent parts that are
compatible specification-wise.
1
2
4
3
5
11
20
1
10
11 20
110
1
2
3
No.
10220-0200EL
2
1
(1)
1.27mm
10120-3000VE
4
10320-52F0-008
1
5
N760D080H01
1
144
(4)
49(9)
22
34
720
(7)
3. 5
27± 0. 2
(3.5)
FCUA-R001
F installation plate
Connector case
Wire material ( flat cable )
Connector
Connector
4-Φ3.5 hole
List of parts used
F installation plate outline dimensio ns drawing
Plate thickness: 1.0mm
Part name / model Manufacturer
Sumitomo 3M
Mitsubishi Electric
pitch flat
Cable length: 10cm
Q’ty
Sumitomo 3M
Sumitomo 3M
[Unit:mm]