Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
Appendix 2 - 3
MDS-D-SVJ3/SPJ3 Series Instruction Manual
Appendix 2-1 CM10-SPxxS-x(D6) plug connector
(4) Soldering a contact
Apply preliminary soldering to each contact and to the cable’s core wire, then solder the core wire to the
contacts.
(Note) Make sure that the core wire does not come out of the contact.
When soldering, make sure that the solder does not stick to the circumference of the solder
cup.
When using a drain wire, attach a heat shrink tube to the drain cable after soldering.
* When making CM10-SP10S-x(D6), the cable for No. 10 terminal is 1mm longer than other
cables. (To avoid the cable tension when inserting a contact to the housing in a later process.)
* The difference in the total A length of the cables for other than No. 10 terminal must be 1mm or
less.
Connector name Applicable contact Applicable cable
CM10-SP10S-x(D6) CM10-#22SC-(S1)(D8) AWG20 or below
CM10-SP2S-x(D6) CM10-#22SC-(S2)(D8) AWG16 or below
A
Detail A
Solder
Contact
Core wire
Cable
Drain wire
Heat shrink tube
Difference in total length: 1 mm or less
(for other than No. 10 terminal)
29 to 32mm
If a drain wire is soldered