Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
6 - 7
MDS-D-SVJ3/SPJ3 Series Instruction Manual
6-2 Protective functions list of units
Detector alarm (Servo drive unit)
(Note) A driver processes all reset types of alarms as "PR". However, "AR" will be applied according to the detector.
Detector alarm (Spindle drive unit)
(Note) A driver processes all reset types of alarms as "PR". However, "AR" will be applied according to the detector.
Alarm number when the detector
is connected to CN2 side
2B 2C 2D 2E 48 49 4A 4B
Alarm number when the detector
is connected to CN3 side
1B 1C 1D 1E 27 28 29 2A
OSA105,
OSA105-ET2
OSA166,
OSA166-ET2
MITSUBISHI
Memory
alarm
LED alarm Data alarm - - - - -
OSA18 CPU alarm - Data alarm - - - - -
MDS-B-HR
Memory
error
- Data error -
Scale not
connected
---
AT343
AT543
AT545
Mitsutoyo
Initialization
error
EEPROM
error
Photoelec-
tric type,
static capac-
ity type data
mismatch
ROM/RAM
error
CPU error
Photoelec-
tric type
overspeed
Static
capacity
type error
Photoelec-
tric type
error
LC193M,
LC493M
RCN223M,
RCN227M
RCN727M,
RCN827M
EIB Series
HEIDENHAIN
Initialization
error
EEPROM
error
Relative/
absolute
position data
mismatch
ROM/RAM
error
CPU error Overspeed
Absolute
position data
error
Relative
position data
error
MPRZ Series MHI
Installation
accuracy
fault
-
Detection
position
deviance
Scale
breaking
Absolute
value detec-
tion fault
- Gain fault Phase fault
SR75, SR85
SR77, SR87
RU77
MAGNE-
SCALE
Laser diode
error
System
memory er-
ror
Encoder
mismatch
error
- - Over speed
Absolute
position
data error
Relative
position data
error
SAM/SVAM/
GAM/LAM
Series
FAGOR --
Absolute
value detec-
tion error
H/W error CPU error - - -
Alarm number when the detector
is connected toCN2 side
2B 2C 2D 2E 48 49 4A 4B
Alarm number when the detector
is connected to CN3 side
1B 1C 1D 1E 27 28 29 2A
TS5690
TS5691
MITSUBISHI
Memory
error
Waveform
error
- - - Overspeed -
Relative
position data
error
MDS-B-HR
Initialization
error
- Data error -
Connection
error
---
OSA18 CPU error-Data error-----
EIB Series
HEIDEN-
HAIN
Initialization
error
EEPROM
error
- - CPU error Overspeed -
Relative
position data
error
MPCI scale MHI
Installation
accuracy
fault
-
Detection
position
deviance
Scale
breaking
- - Gain fault Phase fault