3 - 93
MDS-D-SVJ3/SPJ3 Series Instruction Manual
3-3 Setting the initial parameters for the spindle drive unit
【#3107】 ori_spd Orientation command speed
Set the spindle speed during orientation command.
---Setting range---
1 to 99999 (r/min)
【#3108】 ori_sft In-position shift amount for orientation
Set the orientation stop position.
The clockwise direction when viewed from the load side is considered as minus (-).
---Setting range---
-35999 to 35999 (0.01°)
【#3109】 zdetspd Z phase detection speed
When "#3106/bitF = 0" (Normal), set the spindle speed at initial Z phase detection.
Guideline for the initial setting value is from 50 to 300.
When "#3106/bitF = 1" (Spindle zero point proximity switch detection enabled), set the spindle speed
at initial spindle zero point proximity switch detection.
(Note) When spindle zero point proximity switch detection is enabled, the rotation direction of the
orientation/zero point return (synchronous tapping, spindle/C axis) will follow Z phase
detection direction. And the speed will follow Z phase detection speed. Guideline for the
initial setting value is from 50 to 300.
---Setting range---
1 to 99999 (r/min)
【#3110】 tap_spd Synchronous tapping zero point return speed
Set the synchronous tapping zero point return speed.
---Setting range---
1 to 99999 (r/min)
【#3111】 tap_sft Synchronous tapping zero point return shift amount
Set the synchronous tapping zero point return shift amount.
---Setting range---
0.00 to 35999 (0.01°)
【#3112】 cax_spd Spindle C axis zero point return speed
Set the spindle C axis zero point return speed.
---Setting range---
1 to 99999 (r/min)
【#3113】 cax_sft Spindle C axis zero point return shift amount
Set the spindle C axis zero point return shift amount
---Setting range---
0.00 to 359999 (0.001°)
【#3114】 cax_para_chg Spindle/C axis parameter switch
Select whether to switch detector's parameters between spindle control and C axis control during
spindle/C axis control.
0: Not switch
1: Switch
---Setting range---
0/1 (Standard: 0)