Appendix 2 - 27
MDS-D-SVJ3/SPJ3 Series Instruction Manual
Appendix 2-5 1747464-1 plug connector
(7) Store the receptacle housing and ground clip in the receptacle case.
Pull the cable side and draw the receptacle housing side as shown below, without pushing in it.
Work will become easy when the crimping part of the ground clip is pushed and the cable is bent as
shown below.
When the ground clip interferes with receptacle case at the position below and cause difficulty in
continuing to draw in,
push the ground clip to distort and drawing become easy.
(Note) To prevent a fracture, do not use the ground clip which is bend and unbend 3 times or more.
Pull
Push
Push
Distortion