3-2 Setting the initial parameters for the servo drive unit
#2313 SV113 SSF8 Servo function 8
Select the servo functions.
A function is assigned to each bit.
Set this in hexadecimal format.
bit F : ssc Safety observation function
0: Stop 1: Start
bit E-8 :
Not used. Set to "0".
bit 7 : nmerc Machine error compensation amount
When disabled, the machine error compensation amount including backlash and pitch error to be
compensated by an NC will be ignored by the servo control.
Use this to adjust the lost motion compensation by the electric end roundness measurement.
0: Normal setting 1: Disable
bit 6-0 :
Not used. Set to "0".
#2314 SV114 SSF9 Servo function 9
Select the servo functions.
A function is assigned to each bit.
Set this in hexadecimal format.
bit F-9 :
Not used. Set to "0".
bit 8 : nohis History of communication error alarm between NC and DRV (34, 36, 38, 39)
Set "1" for C70.
0: Enable 1: Disable
bit 7 : cse Command speed monitoring function
0: Normal setting 1: Enable
bit 6-0 :
Not used. Set to "0".
nmerc
ssc
cse
nohis