Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
MDS-D-SVJ3/SPJ3 Series Instruction Manual
2-5 Motor and detector connection
2 - 25
(3) Connecting the linear scale (for rectangular wave signal output)
Rectangular wave signal output (including when SIN wave signal output is converted to the rectangular
wave signal output with a scale manufacturer detector interface unit) can directly input to the drive unit.
(4) Connecting the linear scale (for SIN wave signal output)
SIN wave signal output is converted to Mitsubishi serial signal output with the detector interface unit
(MDS-B-HR).
MDS-D-SVJ3
CN3
CN2
1
3
5
7
9
P5(+5V)
A
Z
B
2
4
6
8
10
LG
A*
B*
Z*
ABZSEL*
No.1 No.9
No.2 No.10
Cable prepared by user
Max. 30m
Linear scale
( Rectangular wave signal output )
Detector type setting
SV025 82xx
CNV2E cable
Max. 30m
Pin No.
Detector connector CN3
Name
Name
Pin Pin
Servomotor
1
3
5
7
9
P5(+5V)
RQ
SD
2
4
6
8
10
LG
RQ*
SD*
CON3
CON4
CON1
CON2
MDS-D-SVJ3
CN3
CN2
No.1 No.9
No.2 No.10
MDS-B-HR-11
Detector interface unit
Cable
prepared
by user
Linear scale
( SIN wave signal output )
Detector type setting
SV025 A2xx
CNV2E cable
Max. 30m
Servomotor
Pin No.
Detector connector CN3
Name
Name
Pin Pin