Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
3 - 136
3 Setup
MITSUBISHI CNC
#13229 SP229 SFNC9 Spindle function 9
Select the spindle functions.
Functions are allocated to each bit.
Set this in hexadecimal format.
bit F : ssc Safety observation function
0: Disable 1: Enable
bit E :
Not used. Set to "0".
bit D : rps Safety observation speed setting unit
0: Normal 1: 100°/min
bit C : sdt2 Specified speed output digital signal 2 output
0: Normal 1: Enable
bit B-0 :
Not used. Set to "0".
#13230 SP230 SFNC10 Spindle function 10
Select the spindle functions.
Functions are allocated to each bit.
Set this in hexadecimal format.
bit F-9 :
Not used. Set to "0".
bit 8 : nohis Communication error alarm(34,36,38,39) between NC and DRV Specific
alarm history disabled
0: Enable 1: Disable
For C70, set "1".
bit 7 : cse Spindle C axis command speed monitoring function
0: Normal setting (function disabled) 1: Function enabled
It is not available for MDS-D-SPJ3 Series.
bit 6-0 :
Not used. Set to "0".
#13231 SP231
Not used. Set to "0".
#13232 SP232
Not used. Set to "0".
cse
nohis