Appendix 2-2 CM10-APxxS-x(D6) angle plug connector
(9) Tightening a clamp nut
[1] Temporarily tighten the clamp nut on the angle back shell.
* To prevent loosening, the adhesive should be applied to the angle back shell.
Recommended adhesive: 1401B (Three Bond Co., Ltd.)
[2] Fix the 2 surface width of the angle back shell on the tightening guide.
[3] Set the tightening wrench adjusting the 2 surface width of the clamp nut.
[4] With the wrench, tighten the clamp nut on the angle back shell.
Recommended tightening torque: 5N•m
(Note1) To set the work to the wrench, adjust the 2 surface width.
In case of squeezing the clamp nut with excessed torque provided as above, the clamp
nut may be broken. Please use the torque wrench.
To remove, take the reverse steps.
Temporary
tightening
* Recommendation
Adhesive
(2 treads around the
circumference)
19
15
Tightening guide
Set
Set
Tighten
Clamp nut wrench
Clamp nut
Angle
Back shell
Torque wrench
Tightening guide
(Back shell width)
* Referential dimensions for back
shell tightening guide
* Recommendation:
Tightening guide
(357J-52658T)
٨Recommended jigs and tools : Clamp nut wrench (357J-51334T)
Bit (357J-51345T)
Torque wrench (CL6N x 8D,Tonichi Mfg.)
* Recommended tightening guide: (357J-52658T)