Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
1 - 10
1 Installation
MITSUBISHI CNC
[3] When installing the servomotor horizontally, set the power cable and detector cable to face downward.
When installing vertically or on an inclination, provide a cable trap.
[4] Do not use the unit with the cable submerged in oil or water.
(Refer to following drawing.)
[5] Make sure that oil and water do not flow along the cable into the motor or detector.
(Refer to right drawing.)
1. The servomotors, including those having IP65 specifications, do not have a completely waterproof
(oil-proof) structure. Do not allow oil or water to constantly contact the motor, enter the motor, or
accumulate on the motor. Oil can also enter the motor through cutting chip accumulation, so be
careful of this also.
2. When the motor is installed facing upwards, take measures on the machine side so that gear oil,
etc., does not flow onto the motor shaft.
Cable trap
CAUTION
Cover
Oil water
<Fault> Capillary tube phenomenon
Servomotor
<Fault> Respiration
Cover
Servomotor