Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
3 - 81
MDS-D-SVJ3/SPJ3 Series Instruction Manual
3-3 Setting the initial parameters for the spindle drive unit
#3007 smax 3 Maximum rotation speed (Gear: 10)
Set the maximum spindle speed with gear 10.
Set this as slimt >= smax.
By comparing the S command value and the values of gear 1 - 4, a spindle gear shift command will
be output automatically.
---Setting range---
0 to 99999 (r/min)
#3008 smax 4 Maximum rotation speed (Gear: 11)
Set the maximum spindle speed with gear 11.
Set this as slimt >= smax.
By comparing the S command value and the values of gear 1 - 4, a spindle gear shift command will
be output automatically.
---Setting range---
0 to 99999 (r/min)
#3009 ssift 1 Shift rotation speed (Gear: 00)
Set the spindle speed for gear shifting with gear 00.
(Note) Setting too large value may cause a gear nick when changing gears.
---Setting range---
0 to 32767 (r/min)
#3010 ssift 2 Shift rotation speed (Gear: 01)
Set the spindle speed for gear shifting with gear 01.
(Note) Setting too large value may cause a gear nick when changing gears.
---Setting range---
0 to 32767 (r/min)
#3011 ssift 3 Shift rotation speed (Gear: 10)
Set the spindle speed for gear shifting with gear 10.
(Note) Setting too large value may cause a gear nick when changing gears.
---Setting range---
0 to 32767 (r/min)
#3012 ssift 4 Shift rotation speed (Gear: 11)
Set the spindle speed for gear shifting with gear 11.
(Note) Setting too large value may cause a gear nick when changing gears.
---Setting range---
0 to 32767 (r/min)
#3013 stap 1 Tap rotation speed (Gear: 00)
Set the maximum spindle speed during tapping cycle with gear 00.
---Setting range---
0 to 99999 (r/min)