Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
3 - 53
MDS-D-SVJ3/SPJ3 Series Instruction Manual
3-3 Setting the initial parameters for the spindle drive unit
#3005 smax 1 Maximum rotation speed (Gear: 00)
Set the maximum spindle speed with gear 00.
Set this as slimt >= smax.
By comparing the S command value and the values of gear 1 - 4, a spindle gear shift command will
be output automatically.
---Setting range---
0 to 99999 (r/min)
#3006 smax 2 Maximum rotation speed (Gear: 01)
Set the maximum spindle speed with gear 01.
Set this as slimt >= smax.
By comparing the S command value and the values of gear 1 - 4, a spindle gear shift command will
be output automatically.
---Setting range---
0 to 99999 (r/min)
#3007 smax 3 Maximum rotation speed (Gear: 10)
Set the maximum spindle speed with gear 10.
Set this as slimt >= smax.
By comparing the S command value and the values of gear 1 - 4, a spindle gear shift command will
be output automatically.
---Setting range---
0 to 99999 (r/min)
#3008 smax 4 Maximum rotation speed (Gear: 11)
Set the maximum spindle speed with gear 11.
Set this as slimt >= smax.
By comparing the S command value and the values of gear 1 - 4, a spindle gear shift command will
be output automatically.
---Setting range---
0 to 99999 (r/min)
(2) Time constant settings during acceleration/deceleration
Set the time constant from the stopped state to reach S commands of smax.
#3101 sp_t 1 Time constant for spindle rotation with S command (Gear: 00)
Set the acceleration/deceleration time constant for spindle rotation using the S command (spindle
control mode = speed operation mode) with gear 00 (Linear acceleration/deceleration pattern).
---Setting range---
0 to 30000 (ms)
#3102 sp_t 2 Time constant for spindle rotation with S command (Gear: 01)
Set the acceleration/deceleration time constant for spindle rotation using the S command (spindle
control mode = speed operation mode) with gear 01 (Linear acceleration/deceleration pattern).
---Setting range---
0 to 30000 (ms)
#3103 sp_t 3 Time constant for spindle rotation with S command (Gear: 10)
Set the acceleration/deceleration time constant for spindle rotation using the S command (spindle
control mode = speed operation mode) with gear 10 (Linear acceleration/deceleration pattern).
---Setting range---