Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
3 - 48
3 Setup
MITSUBISHI CNC
#2324 SV124
Not used. Set to "0".
#2325 SV125
Not used. Set to "0".
#2326 SV126
Not used. Set to "0".
#2327 SV127
Not used. Set to "0".
#2328 SV128
Not used. Set to "0".
#2329 SV129 Kwf Synchronous control feed forward filter frequency
Set the acceleration rate feed forward filter frequency in high-speed synchronous tapping control.
The standard setting is "600".
Related parameters: SV244
---Setting range---
0 to 32767 (rad/s)
#2330(PR) SV130 RPITS Base reference mark interval
Set the base reference mark intervals of distance-coded reference scale. When the distance-coded
reference scale is not used, set to "0".
The interval of basic reference mark (SV130) and auxiliary interval (SV131) must be in the specified
relationship. Other settings cause the initial parameter error (alarm 37).
Following is the specified relationship.
The quotient of (SV130×1000) / SV131 must be 4 or more and leaves no remainder.
Related parameters: SV081/bit7,3, SV131, SV134 to SV137
---Setting range---
0 to 32767 (mm)
#2331(PR) SV131 DPITS Auxiliary reference mark interval
Set the auxiliary interval of reference mark in the distance-coded reference scale. When the
distance-coded reference scale is not used, set to "0".
The interval of basic reference mark (SV130) and auxiliary interval (SV131) must be in the specified
relationship. Other settings cause the initial parameter error (alarm 37).
Following is the specified relationship.
The quotient of (SV130×1000) / SV131 must be 4 or more and leaves no remainder.
Related parameters: SV081/bit7,3, SV130, SV134 to SV137
---Setting range---
0 to 32767 (μm)
#2332 SV132
Not used. Set to "0".
#2333 SV133
Not used. Set to "0".